Western Co LED12.BB-12-350 User Manual Download Page 2

 

 

 

 

User Manual LED12.BB-12/24-

350 

Rev 1.1 

 

22-12-2010

 

 
 
 
 

 

 

 

2 of 2

 

This  document  is  the  property  of  WESTERN  CO. s.n.c.. All rights are reserved. 
Reproduction  and  use  of  information  contained  within  this  document  is 
forbidden without the written consent of  WESTERN CO. s.n.c.. 

Connect  to  the  input  terminal-block  the  power  supplying  cables  +VDC,  -VDC  and  DIMMER,  paying  attention  to 
respect  the  right  polarities.  In  case  of  direct  power  supplying  from  battery  the  connection  causes  the  lamp 
activation and the entry into service of the device. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Lighting  performances:  LED12.BB-12/24-350  has  been  optimized  for  the  projection  ob  billboard  with  90°V  e 
140°H 
 asymmetrical opening angle so to obtain a good uniformity even for a minimum distance of projection.  
Typically  for installation on billboard having dimensions 4x3mt we obtain the following Isolux diagram: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

LED maximum  junction temperature protection: 

In  case  of  high  environment  temperature,  single  LED  string  failure  or  elevated  power  dissipated  on  the  same 
LEDs, the control electronics provide to limit the junction temperature of the LEDs within the limit of 100°C. Such 
a  protection  is  realized  through  micro-controller  control  that  limits  the  supplied  power  through  customized 
software of management Western CO
. This micro-controller allows the power limitation also in case of reduced 
flux.

+ VDC

+ VDC

+ VDC

+ VDC    

----  VDC

  VDC

  VDC

  VDC    

DIMMER

DIMMER

DIMMER

DIMMER    