background image

9

6641-2211

Type tests and environmental conditions

Phenomena

Test

Description

Test levels

ESD

EN 61000-4-2

Enclosure contact 

± 6 kV (crit A)

Enclosure air

± 8 kV (crit A)

RF field AM modulated 

IEC 61000-4-3

Enclosure

20 V/m 80% AM (1 kHz),  
80 – 2500 MHz (crit A)

Fast transient

EN 61000-4-4

Ethernet ports

± 2 kV (crit A)

Earth port

± 2 kV (crit A)

Surge

EN 61000-4-5

Fault port

± 2 kV line to earth (crit A)

Ethernet ports

± 2 kV line to earth (crit A)

Power port

± 2 kV line to earth, ± 2 kV line to line 
(crit A)

RF conducted

EN 61000-4-6

Ethernet ports

10 V 80% AM (1 kHz), 0.15 – 80 MHz 
(crit A)

Power port

10 V 80% AM (1 kHz), 0.15 – 80 MHz 
(crit A)

Power frequency magnetic 
field 

EN 61000-4-8

Enclosure

1000 A/m 50 Hz 
300 A/m 16.7 Hz, 60 Hz, DC (crit A)

Pulse magnetic field

EN 61000-4-9

Enclosure

300 A/m (crit A)

Voltage dips and interruption  EN 50155

DC power ports

10 ms interruption, 100 ms ±40% voltage 
variation

Radiated emission 

CISPR 16-2-3
ANSI C63.4
(FCC part 15)

Enclosure

Class B (30 – 6000 MHz)

Conducted emission

CISPR 16-2-1

DC power port & 
Ethernet ports

Class B

Dielectric strength

EN 50155

Ethernet ports to other 
isolated ports

500 VAC 1 min

Power & Fault port to 
other isolated ports

1500 VAC 1 min

Temperature

EN 60068-2-1
EN 60068-2-2

Operating

–40 to +70ºC

Storage & Transport

–40 to +70ºC

Humidity

EN 60068-2-30

Operating

5 to 95% relative humidity

Storage & Transport

5 to 95% relative humidity

Altitude

Operating

2000 m / 70 kPa

Reliability prediction (MTBF)

MIL-C217F2

Operating

Ground Benign:  

150 years @ 20 ºC
147 years @ 40 ºC
135 years @ 60 ºC

Ground Mobile:  

9,87 years @ 20 ºC
9,85 years @ 40 ºC
9,79 years @ 60 ºC

Ground Fix: 

28,54 years @ 20 ºC
28,43 years @ 40 ºC
27,95 years @ 60 ºC

Service life

Operating

10 year

Vibration, random simulated 
long life 

IEC 60068-2-64,
Cat. 1 class B
(EN 61373)

Not Operating

Vertical: 

7.9 m/s

2

Transverse:  7.9 m/s

2

Longitudinal:  7.9 m/s

2

3 x 5 h

Vibration, random functional

IEC 60068-2-64,
Cat. 1 class B
(EN 61373)

Operating

Vertical: 

1.0 m/s

2

Transverse:  1.0 m/s

2

Longitudinal:  1.0 m/s

2

3 x 10 min

Summary of Contents for Viper 008

Page 1: ...Viper 008 Unmanaged 8 port Ethernet Switch www westermo com ...

Page 2: ...2 6641 2211 ...

Page 3: ...ressed or implied including but not limited to the implied warranties of merchantability and fitness for a particular purpose Westermo reserves the right to revise this document or withdraw it at any time without prior notice Under no circumstances shall Westermo be responsible for any loss of data or income or any special incidental and consequential or indirect damages howsoever caused More info...

Page 4: ...a potentially hazardous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product NOTICE Provides information in order to avoid misuse of the product confusion or misunderstanding No personal injury Minor damage to the product NOTE Used for highlighting general but important infor...

Page 5: ...ousings Westermo recommends a cross sectional area of at least 4 mm2 Upon removal of the product ensure that the protective earthing conductor is disconnected last WARNING HAZARDOUS VOLTAGE Do not open an energized product Hazardous voltage may occur when connected to a power supply WARNING PROTECTIVE FUSE The power supply wiring must be sufficiently fused It must be possible to disconnect manuall...

Page 6: ...t high temperatures the external surface may exceed Touch Temperature Limit according to the product s relevant electrical safety standard CAUTION ELECTROSTATIC DISCHARGE ESD Prevent electrostatic discharge damages to internal electronic parts by discharging your body to a grounding point e g use a wrist strap ...

Page 7: ...king properly contact the place of purchase nearest Westermo distributor office or Westermo technical support Product disposal This symbol means that the product shall not be treated as unsorted municipal waste when disposing of it It needs to be handed over to an applicable collection point for recycling electrical and electronic equipment By ensuring this product is disposed of correctly you wil...

Page 8: ...ent off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Type Approval...

Page 9: ...sion CISPR 16 2 3 ANSI C63 4 FCC part 15 Enclosure Class B 30 6000 MHz Conducted emission CISPR 16 2 1 DC power port Ethernet ports Class B Dielectric strength EN 50155 Ethernet ports to other isolated ports 500 VAC 1 min Power Fault port to other isolated ports 1500 VAC 1 min Temperature EN 60068 2 1 EN 60068 2 2 Operating 40 to 70ºC Storage Transport 40 to 70ºC Humidity EN 60068 2 30 Operating 5...

Page 10: ...ck sawtooth IEC 60068 2 27 Cat 1 class B IEEE1478 2001 Operating Vertical 100 m s2 Transverse 100 m s2 Longitudinal 100 m s2 11 ms 3 x 6 shocks Enclosure UL 94 Nickel coated zinc Flammability class V 1 Dimension W x H x D 175 x 100 x 53 4 mm Weight 0 9 kg Degree of protection IEC 529 Enclosure IP 65 when all ports are protected connected else IP 40 Cooling Convection Mounting DIN Rail or wall moun...

Page 11: ... 154 VDC for 100 ms Rated current 110 mA 24 VDC 33 mA 110 VDC Rated frequency DC Inrush current I2t Max 0 02 A2s 24 110 VDC Polarity Reverse polarity protected Startup current 300 mA 16 8 VDC Redundant power input No Isolation to Connections X1 X8 and to ground 1500 VAC Fault relay belongs to the same isolation group as the power supply lines fault relay signals are also contained within PWR Conne...

Page 12: ... on the power input Description of how connection to the fault contact could be done is shown below The relay is closed when the unit is OK and open at failure The relay is of semiconductor type no moving parts It is specified for max current 250 mA continuous 500 mA peak 10 ms operational voltage up to 110 V protected by a 150 VDC varistor ON resistance less than 10 Ohm and leakage current max 1 ...

Page 13: ... VAC Galvanic connection to None except for shielded contact to housing Connection 4 pole M12 female with D code Shielded cable Not required twisted pair is recommended Conductive housing Nickel plated zinc metal housings of X1 X8 also connected to the housing Number of ports 8 Ethernet X1 X8 Position Direction Description 1 Out Transmit Data 2 In Receive Data 3 Out Transmit Data 4 In Receive Data...

Page 14: ...f Interface ports LEDs LED indicators LED Status Description PWR GREEN Unit indicates no fault RED Unit indicated fault X1 to X8 OFF No Link GREEN Link is up GREEN FLASH Data is transmitted X1 X2 X6 X3 X7 PWR SERVICE X4 X8 X5 ...

Page 15: ...ail This unit can be mounted on 35 mm DIN rail which is horizontally mounted inside an apparatus cabinet or similar Snap on mounting see figure Removal Press down the support at the back of the unit using a screwdriver See figure ...

Page 16: ...airflow around the unit Spacing is recommended for the use of unit in full operating temperature range and service life Wall mounting There are four 6 mm bore holes intended for mounting the unit The unit can be mounted vertical or horizontal Use four M6 screws with 12 mm washer on a flat and stable surface X1 X2 X6 X3 X7 PWR SERVICE X4 X8 X5 ...

Page 17: ...17 6641 2211 Dimensions Measurements are stated in millimeters ...

Page 18: ...REV F 6641 2211 2021 05 Westermo Network Technologies AB Sweden Westermo Metallverksgatan 6 SE 721 30 Västerås Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com ...

Reviews: