Westermo SDW-541-F1G-T4G User Manual Download Page 15

15

6644-2240

LED indicators

 

Indicators

 (LED) 

 

 Power (PWR) 
Link (LINK) of every port 
Speed (SPD) and duplex (DPX) of TX ports

LED

Status

Description

PWR

ON

Internal power, initialising OK

Slow flash

Initialisation progressing

Fast flash

Initialisation error

LINK/SPD

OFF

No Ethernet link

ON

Good Ethernet link

Flash

Ethernet data is transmitted or received, traffic indication

Flash 3 Hz

10 Mbit/s

Flash 6 Hz

100 Mbit/s

Flash 12 Hz 1000 Mbit/s

DPX

OFF

Half duplex

(TX only)

ON

Full duplex

SFP Transceivers

The unit supports Westermo labelled transceivers only.  See Westermo's modular 
transceivers datasheets 100 Mbit and 1 Gbit for supported SFP transceivers. See 
Transceiver User Guide "6100-0000" for transceiver handling instructions.

www.westermo

.com  – A Beijer 

Electronics Gr

oup Compan

y

Gigabit Transceiv

ers

RedFox, Lynx series and OD

W-700 series

The  Westermo

 range of Small

 Form-factor 

Pluggable (SFP)

 transceivers 

covers versions

 suitable for Gigabit

 applications. 

LC connector

s are used as 

standard due 

their small siz

e.

These transceiv

ers have been

 verified to meet

 the  Westermo

 environmental

 specification 

and can oper

ate in a range

  

of different  W

estermo products

 in harsh industr

ial applications.

 The transceiv

ers are coded

 to allow confir

mation that 

certified versions

 have been installed.

Versions are a

vailable with diff

erent wave length

 including 1550

 nm for extreme

 distances upto

 120 km (74.5

 mi)  

and 1310 nm

 version for both

 single (9/125)

 and multimode

 cables (50/125

 and 62.5/125).

 In applications

 where only  

a single fibre 

core is availab

le a Bi-Directional

 (BiDi) transceiv

er can be used.

Wide choice 

to provide optimal

 solution

•  1000 Mbit/s

 versions

•  Standard LC

 connector type

Verified to meet

 Westermo en

vironmental specifications

•  Temperature

 range –40 to

 +85°C (–40 

to +185°F)

•  Coded to guar

antee quality 

Different transciv

ers for many 

solutions

•  Multi mode

 fibre up to 2

 km (1.2 mi)

•  Single mode

 fibre up to 120

 km (74.5 mi)

•  Bi-directional

 fibre transciv

ersup to 120 

km (74.5 mi)

•  Gbit copper

 transceivers

EN 60825-1

 Eye Safety: Class 1 laser pr

oduct complies

Component Recognition

RX

TX

Interfaces

How far can 

we get with 

transceivers

The different 

transceiver options

 are marked with

 an  

indicative range

 as a part of the

 transceiver descr

iption. 

This is the specified

 distance when

 the transceiv

er is used 

in Gbit applications.

For the ODW

 series the maxim

um distance (km)

 can be 

calculated with

 the formula: 

Power budget

 (dB) – signal 

loss (dB) / fibre

 attenuation 

(db) per km.

Signal loss = splice attenuation x number of s con

-

nector attenuation x number of connector

s + safety mar

gin. 

Splice, connector and fibre attenuation can be f

ound on article 

data sheets.

By calculating

 the maximum

 distance based

 on power 

budget a LC2

 multimode tr

ansceiver can

 operate  

up to 5 km (3.1

 mi).

Transceivers 1Gbit_1509_EN_REV

. B

www.westermo

.com  – A Beijer 

Electronics Group 

Company

100 Mbit Transceiv

ers

RedFox, Lynx series and OD

W-700 series

The  Westermo range

 of Small Form-factor

 Pluggable (SFP) transceiv

ers covers versions suitab

le for 10/100 Mbit/s

applications. LC connector

s are used as standard

 due their small size.

These transceivers hav

e been verified to meet

 the  Westermo environmental

 specification

 and can operate in a range

  

of different Wester

mo products in harsh industr

ial applications.

 The transceivers are coded

 to allow confirmation

 that 

certified versions have been

 installed.

Versions are availab

le with different wave length

 including 1550 nm for extreme

 distances upto 120 km

 (74.5 mi)  

and 1310 nm version

 for both single (9/125)

 and multimode

 cables (50/125 and 62.5/125).

 In applications

 where only  

a single fibre core is availab

le a Bi-Directional

 (BiDi) transceiver can

 be used.

Wide choice to provide

 optimal solution

•  100 Mbit/s versions

•  Standard LC connector

 type

Verified to meet Wester

mo environmental

 specifications

•  Temperature range

 –40 to +85°C (–40

 to +185°F)

•  Coded to guarantee

 quality 

Different transcivers fo

r many solutions

•  Multi mode fibre up

 to 2 km (1.2 mi)

•  Single mode fibre

 up to 120 km (74.5

 mi)

•  Bi-directional

 fibre transciversup to 120

 km (74.5 mi)

•  100 Mbit copper

 transceivers

EN 60825-1

 Eye Safety: Class 1 laser pr

oduct complies

Component Recognition

RX

TX

Interfaces

How far can we get 

with transceiv

ers

The different transceiv

er options are marked

 with an  

indicative range as a par

t of the transceiver descr

iption. 

This is the specified

 distance when the transceiv

er is used 

in 100 Mbit applications.

For the ODW series the

 maximum distance

 (km) can be 

calculated with the for

mula: 

Power budget (dB) – signal

 loss (dB) / fibre atten

uation 

(db) per km.

Signal loss = splice attenuation x number of s con

-

nector attenuation x number of connector

s + safety margin. 

Splice, connector and fibre attenuation can be f

ound on article 

data sheets.

By calculating the maxim

um distance based on

 power 

budget a LC2 multimode

 transceiver can oper

ate  

up to 5 km (3.1 mi).

Transceivers 100Mbit_1510_EN_REV

. B

ESD Protection

www.westermo.com

©

W

estermo 

Teleindustri 

AB

User Guide

6100-0000

SFP 

Transceivers

Summary of Contents for SDW-541-F1G-T4G

Page 1: ... Westermo Teleindustri AB www westermo com User Guide 6644 2240 Industrial Ethernet 5 port Switch SDW 500 S E R I E S SDW 541 F1G T4G SDW 550 T5G ...

Page 2: ...icular purpose are made in relation to the accuracy and reliability or contents of this document Westermo reserves the right to revise this document or withdraw it at any time without prior notice Under no circumstances shall Westermo be responsible for any loss of data or income or any special incidental and consequential or indirect damages howsoever caused More information about Westermo can be...

Page 3: ...bre port or any connected fibre although this unit is designed to meet the Class 1 Laser regulations Care recommendations Follow the care recommendations below to maintain full operation of unit and to fulfil the warranty obligations This unit must not be operating with removed covers or lids Do not attempt to disassemble the unit There are no user serviceable parts inside Do not drop knock or sha...

Page 4: ...not it jeopardises the warranty Cleaning of the optical connectors In the event of contamination the optical connectors should be cleaned by the use of forced nitrogen and some kind of cleaning stick Recommended cleaning fluids Methyl ethyl isopropyl or isobutyl alcohol Hexane Naphtha Maintenance No maintenance is required as long as the unit is used as intended within the specified conditions SPE...

Page 5: ...2 2003 DNV GL rules for classification Type Temperature Humidity Vibration EMC Enclosure SDW 541 F1G T4G SDW 550 T5G D B B B A IP21 Corrosive environment Notice This product has been successfully tested in a corrosion test according to IEC 60068 2 60 method 3 This means that the product meets the requirements to be placed in an environment classified as ISA S71 04 class G3 and G4 Note If the produ...

Page 6: ... hazardous substances in electrical and electronic equipment RoHS References of standards applied for this EU declaration of conformity No Title Issue EN 61000 6 1 Electromagnetic compatibility Immunity for residential environments 2007 EN 61000 6 2 Electromagnetic compatibility Immunity for industrial environments 2005 EN 61000 6 4 Electromagnetic compatibility Emission for industrial environment...

Page 7: ...TX shield interface to all other 1 5kV AC 60s duration Environmental Temperatures EN 60068 2 1 EN 60068 2 2 Operating 40 to 74 C 40 to 165 F Storage and transport 50 to 85 C 58 to 185 F Relative humidity EN 60068 2 30 Operating 5 to 95 non condensing Storage and transport 5 to 95 condensation allowed outside packaging Altitude Operating 2 000 m 70 kPa Service life Operating 10 year Reliability pre...

Page 8: ...isolation between all ports power supply and between each chassis screen avoiding ground loop currents The IP21 rating ensures that the unit can be installed in locations where condensed water may occur Only industrial grade components are used which gives an MTBF of 1 182 000 hours for the SDW 541 F1T4G and 1 121 000 hours for the SDW 550 T5G and thus ensures a long service life A wide operating ...

Page 9: ...nge Up to 150 m with CAT5e cable or better Isolation to All other Connection RJ 45 auto MDI MDI X Shielded cable Not required except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails Conductive housing Yes Number of ports SDW 541 F1G T4G 4 SDW 550 T5G 5 Refer to Safety section To minimise the risk of interference a shielded cable is re...

Page 10: ...r connection Network fibre connection Network RJ 45 connection LED indicators Available models SDW 541 F1G T4G 10 100 1000Base T TX 4 ports 100 1000Base FX 1 port SDW 550 T5G 10 100 1000Base T TX 5 ports SDW 541 F1G T4G SDW 550 T5G ...

Page 11: ...t be used 8 7 6 5 4 3 2 1 4 pos screw terminal Description Power 1 COM 0 V 2 DC1 9 6 57 6 VDC 3 DC2 9 6 57 6 VDC 4 COM 0 V Contact Direction Description Remark 1 In Out BI_DA 2 In Out BI_DA 3 In Out BI_DB 4 In Out BI_DC 5 In Out BI_DC 6 In Out BI_DB 7 In Out BI_DD 8 In Out BI_DD Shield In Out Connected to PE F1G 1 SFP slot The F1G interface has one SFP slot supporting Ethernet 100 1000 BaseFX X Ea...

Page 12: ...en configuration via DIP switches the settings of DIP switches configure the unit only after a reboot power off on Observe this when the DIP switches are configured Speed and duplex setting only valid when auto negotiation is disabled When monitoring selected all outgoing packets from the switch is also copied to the port 1 Speed and duplex switch settings are ignored for FX ports If auto negotiat...

Page 13: ... Full duplex selected Half duplex selected Port 5 settings ON 1 2 3 4 5 6 7 8 9 1 0 ON 1 2 3 4 5 6 7 8 9 1 0 ON 1 2 3 4 5 6 7 8 9 1 0 ON 1 2 3 4 5 6 7 8 9 1 0 S2 S2 S2 S2 1000 Mbit s speed selected 100 Mbit s speed selected Full duplex selected Note Only valid for TX SFP Half duplex selected Note Only valid for TX SFP Port settings Port 5 settings ON 1 2 3 4 5 6 7 8 9 1 0 ON 1 2 3 4 5 6 7 8 9 1 0 ...

Page 14: ...S2 Monitoring selected Hub mode ON 1 2 3 4 5 6 7 8 9 1 0 ON 1 2 3 4 5 6 7 8 9 1 0 S2 Hub mode enabled S2 Hub mode disabled Factory settings S1 S2 ON 1 2 3 4 5 6 7 8 9 1 0 ON 1 2 3 4 5 6 7 8 9 1 0 Flow control selected ON 1 2 3 4 5 6 7 8 9 1 0 S2 Flow control selected S2 No flow control selected ON 1 2 3 4 5 6 7 8 9 1 0 ...

Page 15: ...e formula Power budget dB signal loss dB fibre attenuation db per km Signal loss splice attenuation x number of splices con nector attenuation x number of connectors safety margin Splice connector and fibre attenuation can be found on article data sheets By calculating the maximum distance based on power budget a LC2 multimode transceiver can operate up to 5 km 3 1 mi Transceivers 1Gbit_1509_EN_RE...

Page 16: ...tructing the airflow around the unit use the following spacing rules Minimum spacing 25 mm 1 0 inch above below and 10 mm 0 4 inches left right the unit Spacing is recommended for the use of unit in full operating temperature range and service life Press down the black support at the back of the unit see figure CLICK CLICK 10 mm 0 4 inches 25 mm 25 mm Spacing left right recommended for full operat...

Page 17: ...17 6644 2240 ...

Page 18: ...18 6644 2240 ...

Page 19: ...19 6644 2240 ...

Page 20: ... fr www westermo fr Germany info westermo de www westermo de North America info westermo us www westermo us Singapore sales westermo com sg www westermo com Sweden info sverige westermo se www westermo se United Kingdom sales westermo co uk www westermo co uk Other Offices Sales Units Westermo Data Communications Westermo SE 640 40 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail i...

Reviews: