background image

www.westermo.com

SDW-500 series

Industrial Ethernet 5-port Switch

Summary of Contents for SDW-500

Page 1: ...www westermo com SDW 500 series Industrial Ethernet 5 port Switch ...

Page 2: ...2 6644 2214 ...

Page 3: ...s document Westermo reserves the right to revise this document or withdraw it at any time without prior notice Under no circumstances shall Westermo be responsible for any loss of data or income or any special incidental and consequential or indirect damages howsoever caused More information about Westermo can be found at www westermo com About This Guide This guide is intended for installation en...

Page 4: ... a potentially hazardous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product NOTICE Provides information in order to avoid misuse of the product confusion or misunderstanding No personal injury Minor damage to the product NOTE Used for highlighting general but important info...

Page 5: ... earthing terminal only valid for metallic housings Westermo recommends a crosssectional area of at least 4 mm2 If the product does not have a protective earthing terminal then the DIN rail must be connected to protective earth Upon removal of the product ensure that the protective earthing conductor or the connection to earth via the DIN rail is disconnected last WARNING HAZARDOUS VOLTAGE Do not ...

Page 6: ...k directly info a fibre optical port or any connected fibre although the product is designed to meed the Class 1 Laser regulations and complies with 21 CFR 1040 10 and 1040 11 CAUTION ELECTROSTATIC DISCHARGE ESD Prevent electrostatic discharge damages to internal electronic parts by discharging your body to a grounding point e g use a wrist strap CAUTION FIBRE OPTIC HANDLING Fibre optic equipment ...

Page 7: ... working properly contact the place of purchase nearest Westermo distributor office or Westermo technical support Cleaning of the optical connectors In the event of contamination the optical connectors should be cleaned by the use of forced nitrogen and some kind of cleaning stick Recommended cleaning fluids Methyl ethyl isopropyl or isobutyl alcohol Hexane Naphtha Product disposal This symbol mea...

Page 8: ...orts 100Base FX 1 port 3644 0030 SDW 532 MM SC2 10 100Base T TX 3 ports 100Base FX 2 port 3644 0032 SDW 532 SM LC15 10 100Base T TX 3 ports 100Base FX 2 port 3644 0033 SDW 532 MM LC2 10 100Base T TX 3 ports 100Base FX 2 port 3644 0034 SDW 532 SM SC15 10 100Base T TX 3 ports 100Base FX 2 port 3644 0035 SDW 532 SM LC40 10 100Base T TX 3 ports 100Base FX 2 port Simplified EU declaration of conformity...

Page 9: ...644 0019 3644 002x and 3644 003x 3_ Applicable only for 3644 6001 4 Applicable only for 3644 0001 3644 0022 3644 0023 3644 0025 3644 0032 3644 0033 3644 0035 CAUTION CORROSIVE GASES If the product is placed in a corrosive environment it is important that all unused connector sockets are protected with a suitable plug in order to avoid corrosion attacks on the gold plated connector pins Corrosive e...

Page 10: ...peed and duplex of individual TX port by DIP switches Port mirror function is possible to set with DIP switch With the port mirror function active the switch will copy all outgoing traffic to port 1 This can be used to monitor all traffic going out from the switch Packets may be discarded if the total throughput exceeds the port speed of port 1 Fibre optic power budget Model Multimode MM xx2 Singl...

Page 11: ...tch The SDW 550 has been designed to meet high industrial specifications providing very high dependability in harsh environmental conditions Features TX shields individually isolated Wide DC power range 12 48 VDC Wide temperature range Automatic MDI MDI X crossover LED indicators for Power Speed Duplex Link and Traffic Port monitoring 35 mm DIN rail mounting Enable or disable of flow control Examp...

Page 12: ...450 mA SDW 532 MM LC2 450 mA Rated frequency DC Connection Detachable screw terminal Connector size 0 2 2 5 mm AWG 24 12 Ethernet TX Electrical specification IEEE std 802 3 2000 edition Data rate 10 Mbit s or 100 Mbit s manual or auto Duplex Full or half manual or auto Connection SC ST or LC Circuit type Optical Transmission range 100 m Ethernet FX Electrical specification IEEE std 802 3 2000 edit...

Page 13: ...tion Network Fibre connection or RJ 45 connection Network RJ 45 connection LED indicators Available models SDW 550 10 100Base T TX 5 ports SDW 541 10 100Base T TX 4 ports 100Base FX 1 port SDW 532 10 100Base T TX 3 ports 100Base FX 2 ports ...

Page 14: ...ed STP connector might be used 8 7 6 5 4 3 2 1 FX LC Multi or single mode optional Ethernet FX connection 1300 nm singlemode fibre transceiver with LC connector The dust protection plug shall be mounted when no fibre is connected FX ST Multi mode optional Ethernet FX connection 1300 nm multi mode fibre tranceiver with ST connector The dust protection plugs shall be mounted when no fibre is connect...

Page 15: ... DPX of TX ports LED Status Indication of PWR ON Internal power initialising OK Slow flash Initialisation progressing Fast flash Initialisation error LINK OFF No Ethernet link ON Good Ethernet link Flash Ethernet data is transmitted or received traffic indication SPD OFF 10 Mbit s TX only ON 100 Mbit s DPX OFF Half duplex TX only ON Full duplex ...

Page 16: ...not open an energized product Hazardous voltage may occur when connected to a power supply Cooling This product uses convection cooling To avoid obstructing the airflow around the product use the following spacing rules Minimum spacing 25 mm 1 0 inch above below and 10 mm 0 4 inches left right the product Spacing is recommended for the use of prod uct in full operating temperature range and servic...

Page 17: ...when auto negotiation is disabled When monitoring selected all outgoing packets from the switch is also copied to the port 1 Speed and duplex switch settings are ignored for FX ports If auto negotiation and auto MDI MDI X disabled all TX ports support MDI X configuration CAUTION ELECTROSTATIC DISCHARGE ESD Prevent electrostatic discharge damages to internal electronic parts by discharging your bod...

Page 18: ... Mbit s speed selected ON 1 2 3 4 5 6 7 8 S1 Half duplex selected ON 1 2 3 4 5 6 7 8 S1 Full duplex selected Port 2 settings ON 1 2 3 4 5 6 7 8 S1 Auto negotiation and auto MDI MDI X disabled ON 1 2 3 4 5 6 7 8 S1 Auto negotiation and auto MDI MDI X enabled ON 1 2 3 4 5 6 7 8 S1 10 Mbit s speed selected ON 1 2 3 4 5 6 7 8 S1 100 Mbit s speed selected ON 1 2 3 4 5 6 7 8 S1 Half duplex selected ON 1...

Page 19: ...1 2 3 4 5 6 7 8 S2 100 Mbit s speed selected ON 1 2 3 4 5 6 7 8 S2 Half duplex selected ON 1 2 3 4 5 6 7 8 S2 Full duplex selected Port mirroring settings ON 1 2 3 4 5 6 7 8 S2 No monitoring selected ON 1 2 3 4 5 6 7 8 S2 Monitoring selected Flow control selected S3 Flow control selected S3 No flow control selected Factory settings ON 1 2 3 4 5 6 7 8 S1 ON 1 2 3 4 5 6 7 8 S2 S3 ON 1 2 3 4 ON 1 2 3...

Page 20: ...valid when auto negotiation is disabled When monitoring selected all outgoing packets from the switch is also copied to the port 1 Speed and duplex switch settings are ignored for FX ports If auto negotiation and auto MDI MDI X disabled all TX ports support MDI X configuration CAUTION ELECTROSTATIC DISCHARGE ESD Prevent electrostatic discharge damages to internal electronic parts by discharging yo...

Page 21: ... 2 settings ON 1 2 3 4 5 6 7 8 S1 Auto negotiation and auto MDI MDI X disabled ON 1 2 3 4 5 6 7 8 S1 Auto negotiation and auto MDI MDI X enabled ON 1 2 3 4 5 6 7 8 S1 10 Mbit s speed selected ON 1 2 3 4 5 6 7 8 S1 100 Mbit s speed selected ON 1 2 3 4 5 6 7 8 S1 Half duplex selected ON 1 2 3 4 5 6 7 8 S1 Full duplex selected S1 S2 Port 4 settings S2 Auto negotiation and auto MDI MDI X disabled S2 A...

Page 22: ...REV I 6644 2214 2021 01 Westermo Network Technologies AB Sweden Westermo SE 635 35 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com ...