Westermo MCW-211-F1G-T1G User Manual Download Page 8

4

6645-2211

Simplified EU declaration of conformity 

Hereby, Westermo declares that the equipment is in compliance with applicable EU 
directives. The full EU declaration of conformity and other detailed information are 
available at the respective product page at www.westermo.com. .

Type

Approval / Compliance

EMC

EN 50121-4, Railway applications – Electromagnetic compatibility – Emission 
and immproducty of the signalling and telecommunications apparatus
EN 61000-6-1, Immproducty residential environments
EN 61000-6-2, Immproducty industrial environments
EN 61000-6-4, Emission industrial environments

Safety

UL 60950-1, IT equipment

Environmental

NEMA TS 2, Traffic Controller Assemblies with NTCIP Requirements

Corrosive  
environment

:

This product has been successfully tested in a corrosion test according to  

IEC 60068-2-60, method 4

. This means that the product meets the requirements  

to be placed in an environment classified as 

ISA-S71.04 class G4

.

Agency approvals and standards compliance

CAUTION - CORROSIVE GASES

If the product is placed in a corrosive environment, it is important 
that all unused connector sockets are protected with a suitable 
plug, in order to avoid corrosion attacks on the gold plated 
connector pins.

Summary of Contents for MCW-211-F1G-T1G

Page 1: ...www westermo com MCW 211 F1G T1G Industrial Ethernet Media Converter...

Page 2: ...2 6645 2211...

Page 3: ...document Westermo reserves the right to revise this document or withdraw it at any time without prior notice Under no circumstances shall Westermo be responsible for any loss of data or income or any...

Page 4: ...a potentially hazardous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product...

Page 5: ...earthing terminal only valid for metallic housings Westermo recommends a crosssectional area of at least 4 mm2 If the product does not have a protective earthing terminal then the DIN rail must be con...

Page 6: ...directly info a fibre optical port or any connected fibre although the product is designed to meed the Class 1 Laser regulations and complies with 21 CFR 1040 10 and 1040 11 CAUTION ELECTROSTATIC DIS...

Page 7: ...stermo distributor office or Westermo technical support Cleaning of the optical connectors In the event of contamination the optical connectors should be cleaned by the use of forced nitrogen and some...

Page 8: ...2 Immproducty industrial environments EN 61000 6 4 Emission industrial environments Safety UL 60950 1 IT equipment Environmental NEMA TS 2 Traffic Controller Assemblies with NTCIP Requirements Corros...

Page 9: ...lass B 30 6500 MHz Conducted RF emission CISPR 16 2 1 Power port Class B Signal ports Class B Dielectric strength UL 60950 1 Power interface to all other 1 5kV AC 60s duration TX signal interface to a...

Page 10: ...and the power supply and avoids ground loop currents The IP21 rating ensures that the product can be installed in locations where condensed water may occur Only industrial grade components are used wh...

Page 11: ...smission range Up to 150 m with CAT5e cable or better Isolation to All other Connection RJ 45 auto MDI MDI X Shielded cable Not required except when installed in Railway applications as signalling and...

Page 12: ...8 6645 2211 Connections Power connection Network RJ 45 connection LED indicators Available models MCW 211 F1G T1G 10 100 1000Base T TX 1 port 100 1000Base FX 1 port Network Fibre connection...

Page 13: ...be used 8 7 6 5 4 3 2 1 4 pos screw terminal Description Power 1 COM 0 V 2 DC1 9 6 57 6 VDC 3 DC2 9 6 57 6 VDC 4 COM 0 V Contact Direction Description Remark 1 In Out BI_DA 2 In Out BI_DA 3 In Out BI...

Page 14: ...t right the product Spacing is recommended for the use of product in full operating temperature range and service life CLICK CLICK 10 mm 0 4 inches 25 mm 25 mm Spacing left right recommended for full...

Page 15: ...rve this when the DIP switches are configured Speed and duplex settings are only valid when auto negotiation is disabled Speed and duplex switch settings are ignored for the FX port CAUTION ELECTROSTA...

Page 16: ...ected 1 2 3 4 5 6 7 8 9 1 0 Link Fault Forward 1 2 3 4 5 6 7 8 9 1 0 1 2 3 4 5 6 7 8 9 1 0 S2 LFF mode enabled S2 LFF mode disabled S1 S2 Port settings NOTE On DIP switch S1 the following DIP switches...

Page 17: ...ernet link Flash Ethernet data is transmitted or received traffic indication Flash 3 Hz 10 Mbit s Flash 6 Hz 100 Mbit s Flash 12 Hz 1000 Mbit s DPX OFF Half duplex TX only ON Full duplex LFF OFF Link...

Page 18: ...REV I 6645 2211 2021 01 Westermo Network Technologies AB Sweden Westermo SE 635 35 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com...

Reviews: