5.2. Type Tests and Environmental Condition
Environmental
phenomena
Basic standard
Description
Test levels
ESD
EN 61000-4-2
Enclosure
Contact: ±6 kV
Air: ±8 kV
Fast transients
EN 61000-4-4
Power port
± 2 kV
Signal ports
Earth port
± 1 kV
Surge
EN 61000-4-5
Power port
L-E: ± 0.5 kV, 12
Ω
, 9 µF
L-L: ± 0.5 kV, 2
Ω
, 18 µF
L-E: ± 2 kV, 42
Ω
, 0.5 µF
L-L: ± 2 kV, 42
Ω
, 0,5 µF
L-E: ± 2 kV, 12
Ω
, 9 µF
L-L: ± 1 kV, 12
Ω
, 9 µF
Signal ports
L-E: ± 1 kV, 2
Ω
L-L: ± 2 kV, 42
Ω
, 0.5 µF
Power frequency
magnetic field
EN 61000-4-8
Enclosure
300 A/m; 0, 16.7, 50 Hz
Pulsed magnetic field
EN 61000-4-9
Enclosure
300 A/m
Radiated RF immunity
EN 61000-4-3
Enclosure
10 V/m at (80 - 800) MHz)
20 V/m at (800 - 1000) MHz
10 V/m at (1.4 - 2.1) GHz
5 V/m at (2.1 - 2.5) GHz
1 V/m at (2.5 - 2.7) GHz
1 kHz sine, 80% AM
Conducted RF
immunity
EN 61000-4-6
Power port
10 V, 80% AM, 1 kHz; (0.15-80)
MHz
Signal ports
Earth port
Radiated RF emission
CISPR 16-2-3
ANSI C63,4
(FCC Part 15)
Enclosure
Class A
Conducted RF emission
CISPR 16-2-1
ANSI C63,4
(FCC Part 15)
Power port
Class B
Signal ports
Dielectric strength
EN 60950-1
Power port to all
other ports
1.5 kVrms, 50 Hz, 1 min
Signal ports to all
other ports
Table 7. EMC and electrical conditions
Lynx L106/206-F2G