Environmental
phenomena
Basic
standard
Description
Test levels
Temperatures
EN 60068-2-1
EN 60068-2-2
EN 60068-2-14
Operational
-40 to +70°C (-40 to +158°F)
3
Storage and
transport
-55 to +85°C (-67 to +185°F)
Humidity
EN 60068-2-30
Operational
5-95% relative humidity
Storage and
transport
Altitude
Operational
3000 m
MTBF
IEC TR 62380
241981 hours
Vibration
MIL STD 810,
M514.7
(sine)
Operational
5 to 10 Hz, 5.08 mm
10 to 200 Hz, 2.0 g
20 sweep cycles in each axis, 0.9
octave/min
EN 60068-2-64
(random)
Operational,
endurance test
2.3 m/s
2
random, 5 to 2000 Hz,
3 x 4 h
Shock
4
EN 60068-2-27
Operational
20 m/s
2
, 11 ms, 3 x 6 shocks (half
sine)
MIL STD 810,
M516.7
10 g, 11 ms, 3 x 6 shocks (saw tooth)
Weight
1900 gr
Degree of protection EN 60529
Enclosure
IP66
5
Cooling
Convection
Pollution degree
EN 62368-1
PD2
Conformal coating
type
IPC-A-610
Electronic
modules
AR (Acrylic)
Table 9 Environmental and mechanical conditions
3
Refer to "Safety Information" chapter regarding touch temperature
4
The power and Ethernet cables need to be fastened 200 mm or closer to the unit. The same recommendation
applies to the Antenna cables
5
Provided all connectors are connected with IP66 cabling or fitted with protective caps (delivered with the
unit) and tightened to the specified torque