background image

www.westermo.com

         

  

               

                            

Ibex-RT-310 and -320 Series

EN 50155 WLAN Client / Bridge / Access Point

Summary of Contents for Ibex-RT-310 Series

Page 1: ...www westermo com Ibex RT 310 and 320 Series EN 50155 WLAN Client Bridge Access Point ...

Page 2: ...Declaration of Conformity 11 3 Product Description 12 3 1 Product Description 12 3 2 Available models 13 3 3 Hardware Overview 13 3 3 1 Frontside Overview 13 3 3 2 Front Side Label 14 3 3 3 Rear Side Label 14 3 3 4 Interface Ports View 14 3 4 Connector Information 15 3 4 1 Power Input Connection 15 3 4 2 Ethernet Ports 16 3 4 3 Antenna Ports 17 3 5 LED Indicators 17 3 6 Dimensions 17 4 Installatio...

Page 3: ...7 Revision Notes 30 Ibex RT 310 and 320 Series 3 ...

Page 4: ...westermo com 1 2 About This Guide This guide is intended for installation engineers and users of the Westermo products It includes information on safety and regulations a product description installation instructions and technical specifications 1 3 Software Tools Related software tools are available at www westermo com support software tools 1 4 License and Copyright for Included FLOSS This produ...

Page 5: ...ous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product NOTICE Provides information in order to avoid misuse of the product confusion or misunderstanding No personal injury Minor damage to the product NOTE Used for highlighting general but important information No personal i...

Page 6: ...ve earthing terminal only valid for metallic housings Westermo recommends a cross sectional area of at least 4 mm2 Upon removal of the product ensure that the protective earthing conductor is disconnected last WARNING HAZARDOUS VOLTAGE Do not open an energised product Hazardous voltage may occur when connected to a power supply WARNING PROTECTIVE FUSE The power supply wiring must be sufficiently f...

Page 7: ...eratures the external surface may exceed Touch Temperature Limit according to the product s relevant electrical safety standard This product complies with Touch Temperature Limits throughout its operational temperature range CAUTION CORROSIVE GASES If the product is placed in a corrosive environment it is important that all unused connector sockets are protected with a suitable plug in order to av...

Page 8: ...d not be kept unpowered for more than 30 days 2 4 Product Disposal This symbol means that the product shall not be treated as unsorted municipal waste when disposing of it It needs to be handed over to an applicable collection point for recycling electrical and electronic equipment By ensuring the product is disposed of correctly you will help to reduce hazardous substances and prevent potential n...

Page 9: ...chanical Shock and vibration EN 61373 category 1 class A and B EN 50125 3 Outside the track Insulation Coordination and test EN 50124 1 Railway applications Insulation coordination EN 50155 Railway applications Electronic equipment used on rolling stock Radio communication ETSI EN 300 328 Wideband transmission systems Data transmission equipment operating in the 2 4 GHz ISM band and using wide ban...

Page 10: ...res Reorient or relocate the receiving antenna Increase the separation between the unit and receiver Connect the product into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help NOTE This product contains FCC ID 2AEJD 103902 DT50RF NOTE The Ibex RT 320 LV is registered for 4 9 GHz public safety band with th...

Page 11: ... Tekfun 2 GHz 4 5 dBi max 5 GHz 7 dBi max 1 2 3 1001 Patch SPA 2400 75 8 0 V Huber Suhner 2 GHz 8 dBi max 1 2 3 1000 Patch SPA 5600 40 14 0 V_2 Huber Suhner 5 GHz 14 dBi max 1 2 1002 Patch SPA 5600 65 9 0 MIMO Huber Suhner 5 GHz 9 dBi max 1 2 3 1003 Shark SPA 5600 45 12 10 V Huber Suhner 5 GHz 12 dBi max 1 2 1004 Shark SPA 5600 45 12 10 V Huber Suhner 4 GHz 12 dBi max 1 2 1009 Table 2 Certified an...

Page 12: ...and through SNMP WebGUI The Ibex RT 310 och Ibex RT 320 is designed to withstand tough environmental conditions and can be remotely managed using web browser or SNMP management tools Integrating hardware software and network design support tools this router platform offers advanced capabilities the lowest total cost of ownership and will create the most reliable and resilient networks The product ...

Page 13: ... 320 HV EU Europe 72 110 VDC 3623 072102 Ibex RT 320 HV NA North America 72 110 VDC Table 3 List of available models 3 3 Hardware Overview 3 3 1 Frontside Overview DC OPR ERR X1 X2 5 6 1 2 3 4 7 No Description 1 LED indicators 2 Gigabit Ethernet ports X1 and X2 3 Protective earth terminal 4 Power input DC 5 Frontside label 6 Warning symbol for surface temperatures above 60 C 7 Antenna ports A1 to ...

Page 14: ... AAAAAAAAARR 1 VV SSSSSSSS YYWW AAAAAAAAA Article number RR Region code VV Product revision SSSSSSSS Serial number YY Manufacturing Year WW Manufacturing Week Table 5 Front side label 3 3 3 Rear Side Label Type Ibex RT xxx xx EU IP66 Art No xxx xxxxxx NPN xxxxxx Max current 0 6A Power 24VDC 30 Country of origin Switzerland FCC IC e label http ip address Default IP 192 168 1 20 Westermo Neratec AG ...

Page 15: ...ing Position Direction Description DC 1 DC Positive terminal 2 3 DC Negative terminal 4 Housing Shield Chassis of product ground Table 7 M12 A coded 4 pin male power connector according to IEC 61076 2 101 NOTE If the product is powered by PoE the protective dust cap which is part of the delivery must be closed to protect the power interface from water or dust ingress Ibex RT 310 and 320 Series 15 ...

Page 16: ... 6 In Out DD 7 In Out DC 8 In Out DC Housing Shield Chassis of product ground Table 8 M12 X coded 8 pin female Ethernet connector according to IEC 61076 2 109 Position Device mode A Device mode B 1 DC 2 DC 3 DC 4 DC 5 DC 6 DC 7 DC 8 DC Table 9 Ethernet PoE connection on X2 LV model only NOTE PoE is supported on X2 for the LV product variant only NOTE If the Ethernet function is not used the protec...

Page 17: ...wise the product might be damaged when power is applied to a non terminated antenna port NOTE To ensure specified IP protection suitable QMA connectors cables and terminations must be used 3 5 LED Indicators DC OPR ERR X1 X2 Figure 5 LED indicators LED Description DC Power status OPR Operation status ERR Error status X1 Ethernet status for X1 port X2 Ethernet status for X2 port Table 10 LED indica...

Page 18: ...Figure 6 Dimensional drawing 18 Ibex RT 310 and 320 Series ...

Page 19: ...ensure proper heat dissipation NOTE For outdoor installation consider additional protection against sun radiation dust and dirt to optimize ambient temperature range NOTE Unused connectors must be covered by a protective cap delivered with the product tightened to the specified torque in order to fulfill the specified ingress protection code 4 2 Factory Reset To reset the product into factory defa...

Page 20: ...a cross section of at least 4 mm2 shall be used The grounding wire is set below the rip lock washer The nut is fixed for good reliable grounding contact The tightening torque of the nut shall be 2 0 Nm DC ETH2 ETH1 Figure 7 Earth connection NOTICE Do not use equipment without protective earth connection 4 4 Connection of Cables Recommended tightening torque for the M12 connectors is 0 6 Nm All M12...

Page 21: ...ow is not blocked and that there is enough spacing around the product Figure 8 Installation with reduced natural convection airflow Figure 9 Installation with natural convection airflow When operating the product at high ambient temperatures it is recommended to mount the product to a metallic base plate to improve the heat dissipation The base plate increases the surface to spread the heat Figure...

Page 22: ... Improve installation conditions or RF parameters in case of any temperature alarms 4 6 Replacement of Product Disconnect all cables and unscrew the product from the wall Mount the replacement product and reconnect all cables observing the instructions in Connection of Cables MTTR Mean Time To Repair i e time for replacement of product is 10 minutes CAUTION HOT SURFACE Be aware that the surface of...

Page 23: ...2 at 110 VDC Startup currenta 2 x nominal current Polarity Reverse polarity protected Redundant power input No Conductor cross section flexible 0 5 mm AWG 20 Cable temperature rating 40 to 70 C Shielded cable Not required aRecommended external supply current capability for proper startup PoE PoE powered product Ibex RT 310 LV and Ibex RT 320 LV only on X2 Connector M12 X coded female Device mode A...

Page 24: ...A female Direction Transmit and receive Cabling 50 Ohm coaxial cable and WLAN antenna required Conductive chassis Yes WLAN interface High power 3x3 MIMO 802 11n Access Point Client WLAN frequency bands 2 400 to 2 4835 GHz 4 940 to 4 990 GHz 5 150 to 5 350 GHz 5 470 to 5 725 GHz 5 725 to 5 850 GHz Transmitting power Ibex RT 310 Max conducted combined transmit power within the whole frequency range ...

Page 25: ...st be terminated with 50 Ohm terminations NOTICE To avoid damages on the antenna interfaces ensure that the far end side of the antenna cable and or the antenna itself is connected to protective earth Ibex RT 310 and 320 Series 25 ...

Page 26: ...losure 300 A m Radiated RF immunity EN 61000 4 3 Enclosure 20 V m 80 AM 1 kHz at 80 MHz to 2 7 GHz 3 V m 80 AM 1 kHz at 2 7 GHz to 6 GHz 30 V m PM 200 Hz square at 380 MHz to 385 MHz 30 V m PM 200 Hz square at 390 MHz to 395 MHz Conducted RF immunity EN 61000 4 6 DC power port 10 V 80 AM 1 kHz from 0 15 to 80 MHz Ethernet ports Antenna ports Radiated RF emission CISPR 16 2 3 Enclosure Class B FCC ...

Page 27: ...s2 random 5 to 2000 Hz 3 x 4 h Shockb EN 60068 2 27 Operational 100 m s2 30 ms 3 x 6 shocks half sine MIL STD 810 M516 7 20 g 11 ms 3 x 6 shocks saw tooth Weight 1100 gr Degree of protection EN 60529 Enclosure IP66c Cooling Convection Pollution degree EN 62368 1 PD2 Conformal coating type IPC A 610 Electronic modules AR Acrylic aRefer to Safety and Regulations chapter regarding touch temperature b...

Page 28: ...ischarge ETSI European Telecommunications Standards Institute FCC Federal Communication Commission FLOSS Free Libre Open Source Software HV High Voltage IEC International Engineering Consortium IC Industry Canada ID Identification I O Input Output IP Ingress Protection ISO International Standardization Organisation LAN Local Area Network LED Light Emitting Diode LV Low Voltage MIMO Multiple Input ...

Page 29: ...erial Number SNMP Simple Network Management Protocol VPN Virtual Private Network WebGUI Web Graphical User Interface WeConfig Westermo Configuration Tool WEEE Waste Electrical and Electronics Equipment WLAN Wireless Local Area Network Table 13 Abbreviations and terms Ibex RT 310 and 320 Series 29 ...

Page 30: ...sed order 3 5 Led Indicatiors illustration added 4 2 Factory Reset moved from old chapter 3 6 4 5 Cooling illustrations updated Rev F 2021 06 3 4 2 Updated D code X code Rev E 2021 05 Regulatory statements updated for public safety band in chapter 2 5 2 2 5 4 2 5 5 and table 13 Note in chapter 2 3 updated Rev D 2021 03 Product illustrations updated to blue text in illustrations removed Westermo ad...

Page 31: ...Westermo Metallverksgatan 6 SE 721 30 Västerås Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com 6623 2270 REV G 2021 10 Westermo Network Technologies AB Sweden ...

Reviews: