15
6616-2211
Getting started
IP Address
The default IP address of the EDW-120 when delivered is 169.254.100.100
Default port 9000 (A: RS-232)
Default port 9001 (B: RS-232)
Default gateway 169.254.100.1
IP address configuration
The IP address is configurable by the Web tool and/or by using a terminal program.
Below is an description of how to configure the IP address by using a terminal program.
1.
Connect the serial A: RS-232 interface to a terminal program with settings:
Data rate:
9600 bit/s
Data bits:
8
Stop bits:
1
Parity:
None
Flow control: None
EDW-120
DTE
33
22
77
88
66
55
11
44
99
33
22
77
88
66
55
11
44
99
Computer
DTE
Note!
When connecting EDW-120 to a
Comport in a computer you have to use
a “null-modem” cable, because
both EDW-120 and the computer
interface is DTE.
ON
1 2 3 4 5 6 7 8
The Telnet diagnostic service provide the user with information such as UDP- or TCP
mode, connected or listening state (TCP) etc.
C:\WINDOWS\System32\telnet.exe
Westermo EDW-120
login: edw120
Password: ******
Hello edw120
Welcome to Westermo EDW-120 diagnostics service
(TCP Server): Listening for TCP connection on port: [9000]...
2.
Setting DIP S1:1 to ‘On’ and power-up the
EDW-120 this will enable the local IP address
to be configured via serial interface.
Once connected with the terminal program you can change the IP address, Gateway
address and Subnet Mask according to the picture below: