background image

www.westermo.com

EDW-120

Serial Adapter

Summary of Contents for EDW-120

Page 1: ...www westermo com EDW 120 Serial Adapter...

Page 2: ...2 6616 2211...

Page 3: ...lity and fitness for a particular purpose are made in relation to the accuracy and reliability or contents of this document Westermo reserves the right to revise this document or withdraw it at any ti...

Page 4: ...a potentially hazardous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product...

Page 5: ...earthing terminal only valid for metallic housings Westermo recommends a crosssectional area of at least 4 mm2 If the product does not have a protective earthing terminal then the DIN rail must be con...

Page 6: ...tion line cords with a cable diameter of AWG 26 or larger Regarding power cable dimensions see Interface Specifications CAUTION ELECTROSTATIC DISCHARGE ESD Prevent electrostatic discharge damages to i...

Page 7: ...n a manner not according to specification the protection provided by the equipment may be impaired If the product is not working properly contact the place of purchase nearest Westermo distributor off...

Page 8: ...FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radia...

Page 9: ...c field EN 61000 4 9 Enclosure 1000 A m 6 4 16 s pulse Radiated emission CISPR 16 2 3 Enclosure EN 61000 6 4 ANSI C63 4 FCC part 15 Conducted emission CISPR 16 2 1 DC power ports EN 61000 6 4 Dielectr...

Page 10: ...sing a broadcast address or multicast addressing Network Serial Device Configured as UDP or TCP server Configured as UDP or TCP client Serial Device Serial Master Serial Slave Serial Slave Serial Slav...

Page 11: ...cked into a frame and sent to the remote client The serial channels are possible to configure individually e g individual packing algorithm and data format It is also possible to direct the two serial...

Page 12: ...plications and technical data visit www westermo com The Web tool also includes an integrated help where all functions and modes are described in details More help can be found inside the web tool and...

Page 13: ...tion is UDP or TCP This allows the EDW 120 to be setup as a TCP server or client as well as an UDP product Configuration of the product The EDW 120 can be easly configured via the onboard Web based co...

Page 14: ...NUM SCROLL CAPS Capture Print echo Help Unique features Packing algorithm that enables the user to decide how and when the serial data should be encapsulated in a TCP or UDP data frame and sent out o...

Page 15: ...9 9 3 3 2 2 7 7 8 8 6 6 5 5 1 1 4 4 9 9 Computer DTE Note When connecting EDW 120 to a Comport in a computer you have to use a null modem cable because both EDW 120 and the computer interface is DTE O...

Page 16: ...120 Config that gives the user rights to configure the product with new parameter values This accounts Username and Password can also be configured when the user are logged in as EDW 120 Config Defaul...

Page 17: ...switch S1 2 1 Force this to On and Power up the EDW 120 for at least 5 seconds 2 Force the DIP switch to Off and power cycle the EDW 120 The EDW 120 now contains the factory default settings Note If t...

Page 18: ...parameters into the product or save the parameters to a file Serial IP and Telnet Options EDW 120 are bundled with Serial IP virtual Com port director software The Serial IP use portions of the Telnet...

Page 19: ...g Telnet session Below is an description of how to start a Windows Telnet session and get diagnostics information from the EDW 120 C WINDOWS System32 telnet exe Welcome to Microsoft Telnet Client Esca...

Page 20: ...sts is managed by TCP For larger amounts of data that have to be split between packets TCP provides a method for reliably reassembling the data in the correct order Because of the requirement to estab...

Page 21: ...ng algorithm The default settings are selected to be compatible to most applications but can be optimized to the customer specific application Detailed description can be received from the Web configu...

Page 22: ...Rated frequency DC Maximum inrush current 10 ms 0 13 A2s 48 VDC Power up current 0 3 A Sensitive power supplies need current limit 0 3A Polarity Reverse polarity protected Redundant power input Yes I...

Page 23: ...stem of an installation and may be directly connected to the protective earth Ethernet 1 Electrical specification IEEE std 802 3 2000 Edition Data rate 10 Mbit s or 100 Mbit s auto negotiated or manua...

Page 24: ...Terminal Ready DTR No 5 Signal Ground SG No 6 In Data Set Ready DSR No 7 Out Request To Send RTS No 8 In Clear To Send CTS No 9 N C Not connected RI LED indicators also integrated in the RJ 45 connec...

Page 25: ...ON Full duplex OFF Half duplex Position Direction Signal name Description Remark No 1 In Transmit Transmit data No 2 In Transmit Transmit data No 3 Out Receive Receive data auto polarity No 4 Termina...

Page 26: ...s left right the product Spacing is recommended for the use of product in full operating temperature range and service life 10 mm 0 4 inches 25 mm 25 mm Spacing left right recommended for full operati...

Page 27: ...ation enabled Auto crossover enabled 10 Mbit s ON 1 2 3 4 5 6 7 8 Ethernet Auto negotiation disabled Auto crossover MDI MDIX disabled 10 Mbit s ON 1 2 3 4 5 6 7 8 Ethernet 100 Mbit s when Auto negotia...

Page 28: ...ata Address CTRL MAC XTAL PHY XTAL CLK RESET 5 V 3 3 V 3 3 V 1 5 V Power A Power B Connector I O I O RJ 45 LED stretch D sub SERIAL A Ethernet 1 Power secondary 5 V RS 232 RS 232 Isolation from all ot...

Page 29: ...ticast group A typical application would be a SCADA host computer communicating to a number of PLC s Description In a point to point application the EDW 120 can replace or extend a cable link The dist...

Page 30: ...ware works by creating virtual comms ports on the computer The Virtual comms port can be selected and use in the same way as a hardware based port The Comms redirection software will encapsulate the s...

Page 31: ...REV H 6616 2211 2021 02 Westermo Network Technologies AB Sweden Westermo SE 635 35 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com...

Reviews: