6622-2231 

 29000448

Type tests and environmental conditions

Phenomena

Test

Description

Test levels

ESD

EN 61000-4-2

Enclosure contact 

± 4 kV

Enclosure air

± 8 kV

RF field AM modulated 

EN 61000-4-3

Enclosure

3 V/m 80% AM (1 kHz), 80 – 1 000 MHz,  1 
400 MHz – 2 000

Fast transient

EN 61000-4-4

Signal ports

± 0.5 kV

Power ports

± 1 kV

Surge

EN 61000-4-5

Telecom/Signal ports  ± 0.5 kV line to earth

Power ports

± 2 kV line to earth, ± 2 kV line to line

RF conducted

EN 61000-4-6

Power ports

3V/m 80% AM (1 kHz), 0.15 – 80 MHz

Voltage dips and  
interruption 

EN 61000-4-11

AC power ports

10 & 100 ms, interruption 
10 ms, 30% reduction 
100 ms, 60% reduction 
5000 ms, >95% reduction 
+30% above & –20% below rated voltage

Radiated emission 

EN 55022

Enclosure

Class B

FCC part 15

Class B

Conducted emission

EN 55022

AC power ports

Class A

FCC part 15

AC power ports

Class B

EN 55022

DC power ports

Class B

Temperature

Operating 
DR-260

–20 to +70º Celsius   
–4 to +158º Fahrenheit

Operating 
DR-260 + 3G

–20 to +55º Celsius   
–4 to +131º Fahrenheit

Storage & Transport

–40 to +85º Celsius   
–40 to +185º Fahrenheit

Humidity

Operating

5 to 95% relative humidity

Storage & Transport

5 to 95% relative humidity

Altitude

Operating

2000 m / 70 kPa

Reliability prediction 
(MTBF)

Bellcore  
RQGR at 40°C

131 400 hours 

Enclosure

Pressed steel

Dimension W x H x D

DR-260

239 x 40 x 151 mm 
9.4 x 1.6 x 5.9 inches

DR-260 + 3G

239 x 40 x 159 mm 
9.4 x 1.6 x 6.2 inches

Weight

0.9 kg

Degree of protection

IEC529

Enclosure

IP 40

Cooling

Convection

Mounting

Horizontal on 35 mm DIN-rail or flat on 
level surface

Summary of Contents for DR-260

Page 1: ...SL2 ADSL2 Router www westermo com Westermo Teleindustri AB User Guide 6622 2231 29000448 DR 260 DR 260 DSL Router SIM 1 SIM 2 PWR 0 WLAN DTE DSL 1 2 3 NET SIM DAT 3G GPRS LAN SIGNAL D B1 B2 OH CD DAT ISDN PSTN ...

Page 2: ...a particular purpose are made in relation to the accuracy and reliability or contents of this document Westermo reserves the right to revise this document or withdraw it at any time without prior notice Under no circumstances shall Westermo be responsible for any loss of data or income or any special incidental and consequential or indirect damages howsoever caused More information about Westermo ...

Page 3: ...ecommendations see Installation section Care recommendations Follow the care recommendations below to maintain full operation of unit and to fulfil the warranty obligations This unit must not be operated with covers or lids removed Do not attempt to disassemble the unit There are no user serviceable parts inside Do not drop knock or shake the unit rough handling beyond the specification may cause ...

Page 4: ...lace turn your wireless equipment OFF immediately Hearing Aids Some digital wireless equipment may interfere with some hearing aids In the event of such interference you may want to consult your service provider or call the customer service line to discuss alternatives Other Medical Devices If you use any other personal medical device consult the manufacturer of your device to determine if they ar...

Page 5: ...ern electronic equipment is shielded from RF signals However certain elec tronic equipment may not be shielded against the RF signals from the wireless unit All radio transmitting devices send signals which may cause interference in different elec tronic devices To avoid interference place the units antenna a sufficiently long distance from other electronics Critical applications Cellular units op...

Page 6: ...nd on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Type Approval Complian...

Page 7: ...on technology equipment Emission 2006 A1 2007 EN 55024 Information technology equipment Immunity 1998 A1 2001 A2 2003 EN 61000 3 2 Electromagnetic compatibility EMC Limits Limits for harmonic current emissions 2006 EN 61000 3 3 Electromagnetic compatibility EMC Limits Limitation of voltage changes voltage fluctuations and flicker in public low voltage supply systems 1995 A1 2001 A2 2005 EN 301489 ...

Page 8: ...w rated voltage Radiated emission EN 55022 Enclosure Class B FCC part 15 Class B Conducted emission EN 55022 AC power ports Class A FCC part 15 AC power ports Class B EN 55022 DC power ports Class B Temperature Operating DR 260 20 to 70º Celsius 4 to 158º Fahrenheit Operating DR 260 3G 20 to 55º Celsius 4 to 131º Fahrenheit Storage Transport 40 to 85º Celsius 40 to 185º Fahrenheit Humidity Operati...

Page 9: ...r the equipment access the web configuration send SMS or email log to an FTP as well as many other scenarios With a feature rich software package i e operating system the unit provide functionality usu ally found in very costly competing products Instead of having to resort to expensive reprogramming or equipment change due to network carriers discontinuing their leased line services use the Weste...

Page 10: ...r auto Circuit type SELV Transmission range 100 m 328 ft Isolation to All other Connection RJ 45 auto MDI MDIX Shielded cable Not required except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails Conductive housing Yes Number of ports 4 To minimise the risk of interference a shielded cable is recommended when the cable is located insid...

Page 11: ...0 Mbit Downlink 3 Mbit Uplink Protocol LLC VC MUX encap Ethernet PPPoA PPPoE IPoA Connection RJ 11 Shielded cable Not required except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails Number of ports 1 Standard Annex ITU T G 992 1 ADSL A B non overlap ITU T G 992 3 ADSL2 A B I J L M non overlap ITU T G 992 5 ADSL2 A B I J M non overlap...

Page 12: ...be inserted first For SIM 1 the contacts should be face down For SIM 2 the contacts should be face up Antenna interface optional Connections Power interface cord Cable Description Black VDC Red VDC DSL interface Ethernet interface USB Host Connectors LED Indicators for details see next page RS 232 Interface 25 position Direction Description No 2 In Transmit Data TD No 3 Out Receive Data RD No 4 In...

Page 13: ...lid SIM installed GREEN A valid SIM card is installed in the unit DAT OFF No data is being transferred over the wireless network GREEN Data is being transferred over the wireless network SIGNAL ALL OFF No signal less than 113 dBm 1 LED GREEN Low signal strength between 112 dBm and 87 dBm 2 LEDs GREEN Medium signal strength between 86 dBm and 71 dBm 3 LEDs GREEN Strong signal strength between 70 dB...

Page 14: ...link uplink HSDPA up to 7 2 Mbit s downlink HSUPA up to 2 0 Mbit s uplink Modem Technologies PSTN Requires PSTN option ISDN Requires ISDN option Serial Port Technologies RS 232 Serial Over IP Serial Extender and Virtual Serial Port LAPB Resiliency and High Availability IEEE 802 1D Spanning Tree Protocol STP IEEE 802 1w Rapid STP RSTP Layer 2 Switching IEEE 802 1Q Static VLAN and VLAN Tagging IEEE ...

Page 15: ... PCAP export support Flexible management of configuration and log files Local file management via HTTP FTP TFTP and SCP Load save files from to USB memory stick Upgrade firmware from USB memory stick Flexible alarm event handling system Syslog log files and remote syslog server Port Monitoring SNTP NTP client PPPoA PPPoE client DHCP client DHCP server DDNS Programming Custom Control ScriptBasic ...

Page 16: ...westermo Default DSL Settings DSL Connection type ADSL ADSL2 ADSL2 on Annex A VPI VCI 0 38 Authentication PPPoA Reset set IP address using an RS 232 serial connection If the IP address of the device is unknown the best way to access the unit is by performing a factory reset however in some instances it may be required to only change or set the IP address of the device This can be achieved by conne...

Page 17: ...our PC and then connect the unit to an appropriate PSU and power it up The unit will start to negotiate the DSL connection after approximately 15 20 seconds please note that the default settings might not be appropriate for your specific connec tion Continue reading in order to assure that you have a valid setup Step 2 Configure your PC Make the following changes in your PC IP address 192 168 2 10...

Page 18: ...Login screen After step 3 you will be presented with a login screen which asks for a username and a password Please type in the following Username admin Password westermo Step 5 Welcome screen You have now successfully logged into the unit and are ready to set up your DSL connection Please click on Network under the Configuration menu item ...

Page 19: ...tion via PPPoA Should the default settings not match your connection you can always change the parameters to match your specific details Then click on DSL under the Interface context ADSL Settings per country Country Provider Annex Mode ATM Enc VPI VCI Sweden TeliaSonera A DHCP LLC 8 35 Germany Deutsche Telekom DT B PPPoE LLC 1 32 United Kingdom British Telecom BT A PPPoA LLC 0 38 ...

Page 20: ...0448 In the DSL setup screen you configure the DSL broadband connection according to the information you received from your service provider When you are done please press Apply and then Save to save your configuration ...

Page 21: ...ted access e g SE Some ISPs does not require any username or password and usually provides Internet access via DHCP To setup the DR 260 in those countries ISPs please follow the actions below First change from PPPoA LLC to Bridged Ethernet LLC under PVC Configuration ...

Page 22: ...22 6622 2231 29000448 Make sure that the radio button for Get an IP address automatically using DHCP is selected ...

Page 23: ...atus you see the status of the DSL connection Step 8 Test your connection In your Internet browser type in www westermo com and test your connection you should be able to see the Westermo website You are now ready to use the DR 260 Type the desired IP address into the text box next to IP Address and then press Apply and Save Change the IP address of the unit First follow steps 1 through 5 above Th...

Page 24: ...westermo de www westermo de Austria Westermo Data Communications Tel 43 0 72030 3920 Fax 43 0 2235 86131 info westermo at www westermo at France Westermo Data Communications Bat A 9 Chemin de Chilly FR 91160 Champlan Tel 33 1 69 10 21 00 Fax 33 1 69 10 21 01 infos westermo fr www westermo fr North America Westermo Data Communications 939 N Plum Grove Road Suite F IL 60173 Schaumburg USA Tel 1 847 ...

Reviews: