Environmental
phenomena
Basic
standard
Description
Test levels
Temperatures
EN 60068-2-1
EN 60068-2-2
Operational
-40 to +70°C (-40 to +158°F)
ab
Storage and
transport
-55 to +85°C (-67 to +185°F)
Humidity
EN 60068-2-30
Operational
5-95% relative humidity
Storage and
transport
Altitude
Operational
2000 m
Service life
Operational
20 years according to IEC/TR 62380
MTBF
1: MIL-217F2,
GB, 25°C
(+77°F)
2: IEC 62380
Viper-x12A: 1: 557,000 h
Viper-x12A-T3G: 1: 549,000 h, 2: 561,000 h
Viper-x12A-T5G: 1: 544,000 h
Vibration
IEC 60068-2-6
(sine)
Operational
2 g rms 5-500 Hz, 5 sweeps
IEC
60068-2-64
(random)
Non-operational
long life
simulation
11.44 m/s² rms 5-150 Hz, 5 hours
2.3 m/s² rms 5-2000 Hz, 5 hours
Shock
IEC
60068-2-27
Operational
10 g, 30 ms, half sine
20 g, 11 ms, saw tooth
100 g, 6 ms, half sine
Weight
1.4 kg
Degree of protection
EN 60529
Enclosure
IP67
Cooling
Convection
Overvoltage
category
EN/IEC
61010-1
OVC II
Pollution degree
EN/IEC
61010-1
PD3 macro environment and PD2 micro
environment
c
EN 50124-1
PD2
Location
EN/IEC
61010-1
Outdoor, wet locations
IEEE 1478
Class 1, condition E4. Indoor
a
Refer to "Safety and Regulations" chapter regarding touch temperature
b
Operational at +85°C for a limited time
c
Installation and maintenance shall be made under controlled environments.
Table 11. Environmental and mechanical conditions
Viper 12A Series
23
Summary of Contents for 3635-0010
Page 1: ...www westermo com OS Viper 12A Series 12 port Ethernet M12 switches ...
Page 25: ...Viper 12A Series ...
Page 26: ...Viper 12A Series ...
Page 27: ...Viper 12A Series ...