POWER SUPPLY CONNECTION
There are safety regulations governing the power source that can be used
in conjunction with the product. Refer to chapter Interface Specifications.
3.4.2. I/O Connection
Illustration
Pin no.
Product marking
Direction
Description
1
2
3
4
1
C
Output
Relay output common
2
NO
Output
Relay output normally open
3
DI +
Input
Digital in +
4
DI -
Input
Digital in -
Table 4. I/O connection
The relay output is a potential free, opto-isolated, normally open, solid-state relay. This can
be configured to monitor various alarm events within the unit, see WeOS User guide. An
external load in series with an external voltage source is required for proper functionality.
For voltage/current, see Interface Specifications.
The Digital in is an opto-isolated digital input, which can be used to monitor external
events. For voltage/current, see Interface Specifications.
External load
Status
V
V
Digital in
+
-
+
-
3
4
1
2
Figure 4. Digital in
3.4.3. Console Port
The console port can be used to connect to the CLI (Command Line Interface). The
console connector is a USB-C cable that connects to a FTDI FT232R USB to serial
converter internally. For drivers, refer to
and download the appropriate
VCP driver.
Lynx 3510 PoE