27
U
S
E
R
S
e
c
ti
o
n
(e
n
)
7113126.02 (3-08/13)
1. COMMISSIONING THE BOILER
To light the boiler correctly, proceed as follows:
• Open the gas tap (normally positioned under the boiler);
• Check that the hydraulic pressure in the system is correct ("FILLING THE SYSTEM" section);
• power the boiler;
• press button and switch the boiler to Summer
or Winter
;
• press buttons and to adjust the temperature of the heating circuit
and domestic hot water circuit
in order
to ignite the main burner.
When the boiler is lit, the symbol
will appear on the display.
In the Summer position
the main burner will only ignite if a DHW tap is opened.
During initial ignition, the burner may not ignite (causing the boiler to shut down) until any air in the gas pipes is vented. In
this case, repeat the ignition procedure until gas reaches the burner. Press button
for at least 2 seconds.
Key to SYMBOLS
Operation in the heating mode
Flame present (burner on)
No flame (ignition failure)
Operation in the DHW mode
Generic fault
Resettable fault
No water (low system pressure)
Numerical signal (temperature, code, fault, etc.)
Key to BUTTONS
On / Off / Summer / Winter
Reset
CH temperature adjustment
Information
DHW temperature adjustment
1.1 ADJUSTING THE CH AND DHW FLOW TEMPERATURE
The system must be fitted with an ambient thermostat for controlling indoor temperature.
Adjust the CH
and DHW
delivery temperature by pressing buttons
and
respectively. When the burner is
lit, the display shows the symbol
.
HEATING
: while the boiler is operating in the heating mode, the display shows the flashing symbol
and the heating delivery
temperature (°C).
DHW
: while the boiler is operating in the DHW mode, the display shows the flashing symbol
and the DHW outlet temperature
(°C).
Summary of Contents for Pulsar E
Page 23: ...23 7113126 01 1 05 13 ...
Page 45: ...45 7113126 01 1 05 13 ...
Page 67: ...67 7113126 01 1 05 13 ...
Page 89: ...89 7113126 01 1 05 13 ...
Page 111: ...111 T E L E P Í T Ő I R é s z h u 7113126 02 3 08 13 ...
Page 133: ...133 7113126 01 1 05 13 ...
Page 155: ...155 7113126 01 1 05 13 ...
Page 168: ...7113126 02 3 08 13 168 S E C T I O N C 30 ...
Page 169: ...169 S E C T I O N C 7113126 02 3 08 13 116 ...
Page 170: ...7113126 02 3 08 13 170 S E C T I O N D ...
Page 173: ...173 S E C T I O N F 7113126 02 3 08 13 CG_2518 M M2 A D C E B F G A ext ...
Page 174: ...7113126 02 3 08 13 174 S E C T I O N F 2 1 D A C G H E F B ...