7
926.323.1 - GB
INSTRUCTIONS FOR USERS
10. TROUBLESHOOTING
Do not drain the whole system as filling up with water again causes unnecessary and harmful scale to build up inside the
boiler and the heating elements. If the boiler is not used during winter and is therefore exposed to the danger of frost, add
some specific anti-freeze to the water in the system (e.g.: propylene glycol coupled with corrosion and scale inhibitors). The
electronic boiler management system includes a “frost protection” function for the heating system which, when delivery
temperature falls below 5°C, operates the burner until a delivery temperature of 30°C is reached.
The frost protection function is enabled if:
* the boiler is electrically powered;
* the gas tap is open;
* the system is at the correct pressure;
* the boiler is not blocked.
9. PROLONGED SHUTDOWN. FROST PROTECTION
To RESET the boiler, press and hold down “R” for at
least 2 seconds. If this fault persists, call the Authorised
Service Centre.
N.B.:
5 reset attempts can be performed after which
the boiler shuts down. To reset again, switch off the
boiler for a few seconds.
Figure 3
0607_1205
RESETTABlE
faults
CODE
DISPlAyED
FAULT
CORRECTIVE ACTION
E01
Failed ignition shutdown
Press and hold down “
R
”. for at least 2 seconds. If this fault persists, call the Authorised
Service Centre.
E02
Safety thermostat tripped
Press and hold down “
R
”. for at least 2 seconds. If this fault persists, call the Authorised
Service Centre.
E03
Flue thermostat/ flue pressure switch
tripped
Call the Authorised Service Centre.
E04
Shutdown after 6 consecutive flame
losses
Press and hold down “
R
”. for at least 2 seconds. If this fault persists, call the Authorised
Service Centre.
E05
Delivery probe failure
Call the Authorised Service Centre.
E06
DHW sensor fault
Call the Authorised Service Centre.
E10
Hydraulic pressure switch block
Check that the pressure in the system is correct; See section 6. If this fault persists,
call the Authorised Service Centre.
E25/E26
Probable blocked pump safety trip.
Call the Authorised Service Centre.
E32
Limescale alarm
Call the Authorised Service Centre.
E35
Parasite flame (flamer error)
Press and hold down “
R
”. for at least 2 seconds. If this fault persists, call the Authorised
Service Centre.
E96
Switching off due to reductions in the
power supply
RESET is automatic. If this fault persists, call the Authorised Service Centre.
N.B.:
in case of a fault, the display backlighting flashes together with the error code.
To keep the boiler efficient and safe, have it checked by the authorised Service Centre at the end of every operating period.
Careful servicing ensures economical operation of the system.
Do not clean the outer casing of the appliance with abrasive, aggressive and/or easily flammable cleaners (e.g.: petrol,
alcohol, and so on). Always switch off the appliance before cleaning it (see section 7 “Switching off the boiler”).
11. ROUTINE MAINTENANCE INSTRUCTIONS
Faults are shown on the display with an error code (e.g.: E 01):
Summary of Contents for pulsar D
Page 68: ...68 926 323 1 RU WE STEN 2 3 1 0805_2302 CG_2072...
Page 69: ...69 926 323 1 RU 4 5 1 3 1 1 1...
Page 79: ...79 926 323 1 RU 9 0712_1208 CG_2008 17 230 3 3x0 75 2 8 9 2 L N L N 1 2 18 9 1 2 1 2...
Page 85: ...85 926 323 1 RU 23 13 9912070100 2 2 19 2 2 24 1 25 0903_1901...
Page 87: ...87 926 323 1 RU 28 0808_2601 CG_2078 16...
Page 93: ...93 926 323 1 RU 33 24 F C N R G V B V NTC NTC 0809_1705 CG_2075...
Page 94: ...94 926 323 1 RU 24 C N R G V B V NTC NTC 0809_1706 CG_2076...
Page 95: ...95 926 323 1 RU 1 24 f 1 14 f C N R G V B V 2 NTC 0809_1707 CG_2086...
Page 96: ...96 926 323 1 RU 1 24 1 14 C N R G V B V 2 NTC 0809_1708 CG_2087...
Page 166: ...166 926 323 1 GR 1 2 3 4 2 3 RESET 1 Reset 0805_2302 CG_2072...
Page 167: ...167 926 323 1 GR 4 5 1 3 1 1 C 1 C...
Page 183: ...183 926 323 1 GR 23 13 9912070100 2 CO2 CO 3 cm 19 C1 2 2 CO2 CO 24 1 25 l h mH 2 O 0903_1901...
Page 185: ...185 926 323 1 GR 28 0808_2601 CG_2078 16...
Page 191: ...191 926 323 1 GR 33 24 F C M N R G V B V NTC NTC 0809_1705 CG_2075...
Page 192: ...192 926 323 1 GR 24 C M N R G V B V NTC NTC 0809_1706 CG_2076...
Page 193: ...193 926 323 1 GR 1 24 f 1 14 f C M N R G V B V M2 NTC 0809_1707 CG_2086...