background image

Section DTW-AK0-400-201

030-101586 Rev. B

R

3

bly. Connect the ---48Vdc power wire to the “---” (red) screw

terminal. Connect the other lead to the “+” (black) screw termi-

nal. Connect the green wire to the Chassis Ground screw

terminal. Westell offers a ---48Vdc, 1 Amp Wall Power Supply

(Model WPS4810) that can be purchased separately.

3.5

Facility/Network Interface Connections

Facility-side wiring connections can be made to either a 66-type

wiring block (List 1, 4, 7 or 8) or to screw terminals (List 5).

3.6

Customer Interface Connections

Customer-side wiring connections can be made to the 66-type

wiring block (List 1, 7 or 8) to RJ48C/S modular jacks (List 4, 5

or 8).

3.7

Module Installation

When all wiring is completed and secured, the module(s) may be

installed inside the assembly cover. Refer to the appropriate

practice for optioning and testing information for each module.

When testing is complete and the circuit is functioning correctly,

close and re-lock the cover (Except List 4 Option).

- CAUTION -

Use care when installing and removing modules -

do not force

a module into place

. If a module resists insertion, remove it

and check for obstructions in or near the module’s or shelf’s

connectors and mounting slots. The module may then be

carefully aligned and gently re-inserted.

4.

TESTING & TROUBLESHOOTING

4.1

Testing

This equipment should not be field repaired. If the equipment

is suspected of being faulty, replace it with another unit, op-

tioned identically, and retest. If the replacement unit appears to

operate correctly, the original unit may be faulty and should be

returned to Westell for repair or replacement (Paragraph 6.2).

4.2

Troubleshooting

If trouble is encountered, verify all installer connections to the

assembly and check that the CO power fuse is not blown. Also

verify all module connections and option switch settings, and

verify the modules are making a positive connection with the

shelf connector. If trouble persists, replace the suspect unit and

repeat procedures outlined. These procedures are not designed

to effect repairs or modifications. Any tests beyond those out-

lined herein, or repairs made beyond replacing a faulty unit, are

not recommended and may void the warranty.

5.

CUSTOMER & TECHNICAL SERVICES

5.1

Customer Service & Technical Assistance

If technical or customer assistance is required, contact Westell

by calling or using one of the following options:

Voice: (800) 377-8766

email:

[email protected]

Visit the Westell World Wide Web site at http://

www.Westell.com

for additional information about Westell.

6.

WARRANTY & REPAIRS

6.1

Warranty

Westell warrants this product to be free of defects at the time of

shipment. Westell also warrants this product to be fully function-

al for the time period specified by the terms and conditions

governing the sale of the product. Any attempt to repair or

modify the equipment by anyone other than an authorized West-

ell representative will void the warranty.

6.2

Repair and Return

Westell will repair or replace any defective Westell equipment

without cost during the warranty period if the unit is defective

for any reason other than abuse, improper use, or improper

installation. Before returning the defective equipment, first re-

quest a Return Material Authorization (RMA) number from

Westell. Once an RMA number is obtained, return the defective

unit, freight prepaid, along with a brief description of the prob-

lem, to:

Westell, Inc.

ATTN: R.G.M. Department

880 Enterprise St.

Suite D

Aurora, IL 60504-7940

Replacements will be shipped in the fastest manner consistent

with the urgency of the situation. Westell will continue to repair

or replace faulty equipment beyond the warranty period for a

nominal charge. Contact Westell for details.

7.

SPECIFICATIONS

7.1

Ordering Specifications

To order units, call the telephone number shown in Paragraph

5.1 and please specify a specific model number shown in Table 1.

Summary of Contents for DTWA-K04 Series

Page 1: ...n will be stated in this paragraph 1 3 Product Mounting The K04 is typically mounted on a wall or equipement back board This mounting enclosure is suitable for mounting on concrete or other noncombust...

Page 2: ...hat could result in the risk of fire or electrical shock Never spill liq uid of any kind on the product 3 1 2 Gathering Tools and Supplies The following tools and supplies are required to mount the K0...

Page 3: ...he modules are making a positive connection with the shelf connector If trouble persists replace the suspect unit and repeat procedures outlined These procedures are not designed to effect repairs or...

Page 4: ...N0ARA Barcode 443024 ECI Pending DTWAK04L7 Locking cover and RJ48C S modular jacks wired to 66 type block CLEI Code VAMDP10LRA Barcode 447135 ECI Pending DTWAK04L8 Front Access Mounting with locking c...

Page 5: ...Section DTW AK0 400 201 030 101586 Rev B R 5 DTWAK04L4 DTWAK04L5 DTWAK04L7 DTWAK04L8 Figure 2 DTWAK04 Assemblies...

Page 6: ...t 1 Circuit 2 Circuit 3 Circuit 4 Circuit 1 Circuit 2 Circuit 3 Circuit 4 Mounting Holes Mounting Hole DTWA528 04 Mounting Assembly DTWAK04 List Option 1 NETWORK SIDE CUSTOMER SIDE Ground Lug top side...

Page 7: ...W O O W T R T1 R1 15 16 17 18 Circuit 4 W G G W W BR BR W T R T1 R1 21 22 23 24 Table 3 Network side Connections List 1 CKT COLOR CODE LEAD 66 BLOCK Circuit 1 W BL BL W W O O W T R T1 R1 27 28 29 30 C...

Page 8: ...01586 Rev B R 8 Circuit 1 Circuit 2 Circuit 3 Circuit 4 Mounting Holes Mounting Hole DTWA528 04 Mounting Assembly DTWAK04 List Option 4 NETWORK SIDE Ground Lug top side of mounting CPE CKT 1 Figure 4...

Page 9: ...W W O O W T R T1 R1 3 4 5 6 Circuit 2 W G G W W BR BR W T R T1 R1 9 10 11 12 Circuit 3 W BL BL W W O O W T R T1 R1 15 16 17 18 Circuit 4 W G G W W BR BR W T R T1 R1 21 22 23 24 Table 5 Network side Co...

Page 10: ...e DTWAK04 List Option 5 NETWORK SIDE Ground Lug Circuit 1 Circuit 2 Circuit 3 Circuit 4 CUSTOMER SIDE Sockets For 5 Pin type Protectors 2 Protectors Required Per Circuit DTWA528 04 Mounting Assembly t...

Page 11: ...Circuit 3 Circuit 4 Circuit 1 Circuit 2 Circuit 3 Circuit 4 Mounting Holes Mounting Hole DTWA528 04 Mounting Assembly NETWORK SIDE CUSTOMER SIDE Ground Lug top side of mounting NOTE Slide Switches loc...

Page 12: ...ions List 7 CKT COLOR CODE RJ PIN LEAD RJ48C LEAD RJ48S 66 BLOCK W BL 5 T 27 BL W 4 R 28 Circuit 1 W O 2 T1 T 29 Circuit 1 O W 1 R1 R 30 W BR 7 T1 31 BR W 8 R1 32 W BL 5 T 33 BL W 4 R 34 Circuit 2 W O...

Page 13: ...04 List Option 8 Circuit 1 Circuit 2 Circuit 3 Circuit 4 Circuit 1 Circuit 2 Circuit 3 Circuit 4 NETWORK SIDE CUSTOMER SIDE Gnd Lug Mounting Hole Gnd Lug Mounting Hole Mounting Hole Mounting Hole Gnd...

Page 14: ...ions List 8 CKT COLOR CODE RJ PIN LEAD RJ48C LEAD RJ48S 66 BLOCK W BL 5 T 27 BL W 4 R 28 Circuit 1 W O 2 T1 T 29 Circuit 1 O W 1 R1 R 30 W BR 7 T1 31 BR W 8 R1 32 W BL 5 T 33 BL W 4 R 34 Circuit 2 W O...

Reviews: