background image

Equipment Issue 1

030-101586 Rev. B, June 2006

Section DTW-AK0-400-201

R

E

Copyright 2006

E

Westell, Inc. All rights reserved. Printed in the United States of America.

*CLEI is a trademark of Telcordia Technologies. Westell

r

is a trademark of Westell, Inc.

Page 1 of 14

Westell Model DTWA-K04 Series

4-Position Pre-Wired Mounting Kit

CONTENTS

PAGE #

1. GENERAL

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2. APPLICATIONS

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3. INSTALLATION

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4. TESTING & TROUBLESHOOTING

3

. . . . . . . . . . . . .

5. CUSTOMER & TECHNICAL SERVICES

3

. . . . . . . . .

6. WARRANTY & REPAIRS

3

. . . . . . . . . . . . . . . . . . . . . . .

7. SPECIFICATIONS

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.

GENERAL

1.1

Document Purpose

This document describes the Westell DTWAK04 Series, shown

in Figure 1. This series of mounting kits are pre-wired wall-

mountable kits equipped with a Westell 4-slot mounting and a

66-type punch-down block or terminal block for making facility-

side and customer-side wiring connections.

- NOTE -

Hereafter, the DTWAK04 will be referred to as the “K04”.

1.2

Document Status

This document is being updated to correct a labeling error in

Figure 6, on page 11. The Circuit 1 label was printing over the

Circuit 2 label.

Whenever this practice is updated, the reason will be stated in

this paragraph.

1.3

Product Mounting

The K04 is typically mounted on a wall or equipement back-

board. This mounting enclosure is suitable for mounting on

concrete or other noncombustible surfaces only.

1.4

Product Features

The K04 offers the following features.

S

Quick Installation

Figure 1.

Front View of DTWAK04 Pre-Wired

Mounting Kit

S

Pre-wired-mountable package with backplate, mounting

assembly and wiring block

S

Bridging clips on both the Network and Customer side of

the 66 block or Krone block (List 1, 4, 7 or 8)

S

Optional primary lightning protection (List 5)

S

Easy access to the plug-in modules

S

Meets UL1950 requirements

S

Meets NEBS Level 3 requirements

2.

APPLICATIONS

The K04 will accommodate up to four 200 MECHANICS

r

-type

modules or up to two 400-type HDSL, DS1, Analog, Data and/or

DDS-type circuits.

3.

INSTALLATION

Installation consists of inspecting the equipment for damage,

following proper safety precautions. Mounting hardware to

install this assembly to a wall or backboard is included. The as-

sembly should be installed so that the 4-slot mounting is in an

upright (vertical) position. The assembly should be located in an

area that provides enough room and adequate lighting. Stan-

dard hand tools are required to install the K04.

Summary of Contents for DTWA-K04 Series

Page 1: ...n will be stated in this paragraph 1 3 Product Mounting The K04 is typically mounted on a wall or equipement back board This mounting enclosure is suitable for mounting on concrete or other noncombust...

Page 2: ...hat could result in the risk of fire or electrical shock Never spill liq uid of any kind on the product 3 1 2 Gathering Tools and Supplies The following tools and supplies are required to mount the K0...

Page 3: ...he modules are making a positive connection with the shelf connector If trouble persists replace the suspect unit and repeat procedures outlined These procedures are not designed to effect repairs or...

Page 4: ...N0ARA Barcode 443024 ECI Pending DTWAK04L7 Locking cover and RJ48C S modular jacks wired to 66 type block CLEI Code VAMDP10LRA Barcode 447135 ECI Pending DTWAK04L8 Front Access Mounting with locking c...

Page 5: ...Section DTW AK0 400 201 030 101586 Rev B R 5 DTWAK04L4 DTWAK04L5 DTWAK04L7 DTWAK04L8 Figure 2 DTWAK04 Assemblies...

Page 6: ...t 1 Circuit 2 Circuit 3 Circuit 4 Circuit 1 Circuit 2 Circuit 3 Circuit 4 Mounting Holes Mounting Hole DTWA528 04 Mounting Assembly DTWAK04 List Option 1 NETWORK SIDE CUSTOMER SIDE Ground Lug top side...

Page 7: ...W O O W T R T1 R1 15 16 17 18 Circuit 4 W G G W W BR BR W T R T1 R1 21 22 23 24 Table 3 Network side Connections List 1 CKT COLOR CODE LEAD 66 BLOCK Circuit 1 W BL BL W W O O W T R T1 R1 27 28 29 30 C...

Page 8: ...01586 Rev B R 8 Circuit 1 Circuit 2 Circuit 3 Circuit 4 Mounting Holes Mounting Hole DTWA528 04 Mounting Assembly DTWAK04 List Option 4 NETWORK SIDE Ground Lug top side of mounting CPE CKT 1 Figure 4...

Page 9: ...W W O O W T R T1 R1 3 4 5 6 Circuit 2 W G G W W BR BR W T R T1 R1 9 10 11 12 Circuit 3 W BL BL W W O O W T R T1 R1 15 16 17 18 Circuit 4 W G G W W BR BR W T R T1 R1 21 22 23 24 Table 5 Network side Co...

Page 10: ...e DTWAK04 List Option 5 NETWORK SIDE Ground Lug Circuit 1 Circuit 2 Circuit 3 Circuit 4 CUSTOMER SIDE Sockets For 5 Pin type Protectors 2 Protectors Required Per Circuit DTWA528 04 Mounting Assembly t...

Page 11: ...Circuit 3 Circuit 4 Circuit 1 Circuit 2 Circuit 3 Circuit 4 Mounting Holes Mounting Hole DTWA528 04 Mounting Assembly NETWORK SIDE CUSTOMER SIDE Ground Lug top side of mounting NOTE Slide Switches loc...

Page 12: ...ions List 7 CKT COLOR CODE RJ PIN LEAD RJ48C LEAD RJ48S 66 BLOCK W BL 5 T 27 BL W 4 R 28 Circuit 1 W O 2 T1 T 29 Circuit 1 O W 1 R1 R 30 W BR 7 T1 31 BR W 8 R1 32 W BL 5 T 33 BL W 4 R 34 Circuit 2 W O...

Page 13: ...04 List Option 8 Circuit 1 Circuit 2 Circuit 3 Circuit 4 Circuit 1 Circuit 2 Circuit 3 Circuit 4 NETWORK SIDE CUSTOMER SIDE Gnd Lug Mounting Hole Gnd Lug Mounting Hole Mounting Hole Mounting Hole Gnd...

Page 14: ...ions List 8 CKT COLOR CODE RJ PIN LEAD RJ48C LEAD RJ48S 66 BLOCK W BL 5 T 27 BL W 4 R 28 Circuit 1 W O 2 T1 T 29 Circuit 1 O W 1 R1 R 30 W BR 7 T1 31 BR W 8 R1 32 W BL 5 T 33 BL W 4 R 34 Circuit 2 W O...