6 System Operation
6.1 Operating the Program
Access the Public Safety Signal Booster through a LAN connection. The Signal Booster ships with the
IP address
192.168.0.1
on the
GUI
port.
To connect directly to the Signal Booster from a laptop or PC with a crossover CAT-5E cable or over a
LAN, change the TCP/IP settings on your computer to enable a connection to a host that has a static
IP.
PC Set-up:
Open Control Panel→ Network Connections → Local area connection
Figure 6-1: Network Connection Set-up
1) Select
Use the following IP Address
and enter the IP address
192.168.1.x,
where ‘x’ is any number
from 2 to 254, inclusive, other than 150
2) Ensure that the subnet mask is set to 255.255.255.0
3) Web Browser: Chrome/Internet explorer
Figure 6-2: Web GUI Log in
Username: admin
Password: Password