CS19-URA-003 Installation and User Guide
Product Information and Customer Assistance
Page 4
WESTELL .COM
Copyright © 2021 by Westell, Inc. All Rights Reserved. Westell
®
, ClearLink
®
, Kentrox
®
, and Optima Management System
®
,
EdgeLink
™
are trademarks of Westell, Inc. All other names are trademarks of their respective owners. Information is correct at
time of printing and is subject to change without notice. Westell, Inc. is an Equal Opportunity/Affirmative Action employer.
030-300907 Rev A
Customer Assistance
Complete access including 24x7 technical support for service-affecting
outages is available
with a Westell Support and Services Agreement.
Pre-Sales Support
(9 a.m.-5 p.m. ET Monday-Friday)
1-800-377-8766, option 1
Technical Support
(8:30 a.m.-5 p.m. ET Monday-Friday
1-800-377-8766, option 2
When you call, please have:
•
Hardware & software versions in use
•
Error number and/or exact wording of any screen
messages
•
What happened, and what you were doing when the issue
occurred
•
How you tried to solve the issue.
Product information and resources
www.westell.com
•
Alarms will remain silenced, and
• A short press of the MUTE button will have no effect
º
If the alarms have been permanently muted, repeat the
above step to toggle back to the permanently unmuted state:
•
The MUTE LED will not be lit,
•
Audible alarms will sound, and
• A short press of the MUTE button will mute alarms as
described above
3. RA-2 Enable Switch
At lower left center of the URA interface unit circuit board is a
switch module with four switches (see Figure 2). The leftmost
of these switches is labeled RA 2 Enable. This switch enables or
disables monitoring of the communication link RA2. With the
switch in the off position RA2 is not operational.
º
Set the switch to On to enable RA-2
º
Set the switch to Off to disable RA-2.
4.
Testing the Remote Annunciators
Check each indicator on each Remote Annunciator while
following the testing procedure for your BDA alarms
(refer
to your BDA installation and user guide)
. The indicator should
illuminate and the audible alarm should sound during each
alarm condition.
Important Product Information
1.
Registration number
A product label with the URA Interface Unit’s product
registration number and bar code is affixed to the right exterior
side of the unit. See Figure 1.
2.
Ordering Specifications
Part Number
Description
CS19-URA-003
Universal Remote Annunciator,
Interface Unit, and one Remote
Annunciator
CS40-ANNUNC
Second remote annunciator for
dual RA installations
3. Electrical Specifications
Specification
Description or Value
Operating voltage
24 or 48 VDC
Communications link
Serial data
Maximum distance, UI to RA
3,000 feet
(914.4 m)
Technical Specification Description
Interface Unit
Weight
6.2 lbs
(2.81 Kg)
Dimensions
11.75”H x 8.7”W x 2.6”D
29.84 cm H x 22.1 cm W x 6.6 cm D
Mounting
Wall Mountable
Feedthroughs
2 x 3/4” conduit
1 x 1/2” conduit
Weatherproofing
NEMA Type 4, listed to UL 508A
Connectors
Alarm Inputs
Compression screw terminals
Alarm Outputs to FACP
Screw terminals
To Remote Annunciator
RJ45 jacks
DC Power Inputs
Compression screw terminals
Remote Annunciator
Dimensions
6.1”H x 5.1”W x 1.1”D
15.49 cm H x 12.95 cm W x 2.79 cm D
Weight
1.5 lbs.
Mounting
2 Gang Electrical Box or Wall
Mount
Weatherproofing
NEMA Type 1
Connectors
To interface unit
RJ45 jack
4.
Mechanical Specifications