background image

West Mountain Radio

Status LED, Low Voltage Disconnect (LVD) 

& High Voltage Disconnect (HVD) Operation

When the RIGrunner 4007U is ON and the input voltage 

is within the normal range the status LED will be GREEN.

If the input voltage is outside of the range, the LED 

will change to RED and the Powerpole

®

 outputs will be 

switched OFF. When input voltage returns to the normal 

range the LED will change to green and the outputs 

enabled. When the RIGrunner 4007U is turned OFF the 

LED will also be OFF.

 

External Sense Input

The external sense terminal is comprised of two pins on 

the left side of the unit accessible through a “knockout” 

panel.  The terminal provides a sense input and +5VDC 

through a 330 ohm resistor and is suitable for a variety of 

mechanical and electrical interlock circuits.

With the RIGrunner facing you (Powerpole

®

 at the 

bottom) the orientation of the terminal is:

 

Top Pin: 5VDC

 

Bottom Pin: Sense Input

External voltage may be used for the sense input or you 

can use the supplied 5VDC.

The included RED lockout jumper may be installed to 

prevent the unit from being turned on.

USB Charging

The USB port may be used to provide power to USB 

devices, such as phones and tablets. The USB port 

follows both the USB Organization’s dedicated charge 

port (DCP) specification and Apple’s unique charge port 

- meaning both Apple or Android phones and tablets or 

DCP devices may be charged.

The USB port contains a 5V regulator that can provide up 

to 2A current. However, the USB DCP and Apple devices 

are requested by the 4007U to limit their load currents; 

Apple devices are limited to 1A and DCP devices are 

limited to 1.5A.

Specifications

Overall Dimensions 

(max., w/o cables)

 

0.9”H x 9.7”W x 3.2” D

Weight  

12.75 oz.

Voltage Readout Accuracy   +/- 2% +1 Count

Current Readout Accuracy   Less than 5A: +/- 0.25A,  

 

5A to 40A: +/- 1A

High Trip  

15V Typical

Low Trip  

11V Typical

Auto Re-Start  

13V Typical

Switching time, High Trip  

15 milliseconds

Switching Time, Low Trip  

3.3 seconds

Summary of Contents for rigrunner 4007u

Page 1: ...inradio com 1020 Spring City Drive Waukesha WI 53186 262 522 6503 sales westmountainradio com 2015 West Mountain Radio All rights reserved All trademarks are the property of their respective owners RI...

Page 2: ...and accessories especially those that draw large amounts of current Locate your power source as close as possible to the RIGrunner Remember that every wire has resistance longer wires have more resis...

Page 3: ...s draw less than 3 amps in receive but require many more amps in transmit Therefore the limiting factor is total current draw while transmitting To determine how many radios may be used to transmit at...

Page 4: ...an A Push button The push button is used for the following functions 1 Pressing the button momentarily while the RIGrunner is turned ON will toggle the display mode to show voltage locked current lock...

Page 5: ...Operating Manual Powerpole Outputs 1 7 Powerpole Input...

Page 6: ...s Top Pin 5VDC Bottom Pin Sense Input External voltage may be used for the sense input or you can use the supplied 5VDC The included RED lockout jumper may be installed to prevent the unit from being...

Page 7: ...Red Black Wire w powerpole ends 15A Powerpole Connector 12 Pair 58257 1093 30A Powerpole Connector 12 Pair 58257 1095 45A Powerpole Connector 12 Pair 58257 1099 Powerpole Retention Clips 12 Pack 58257...

Page 8: ...full explanation and necessary proof of purchase The device or accessory will be repaired or replaced at our option without charge and returned to you at our shipping expense Repaired or replaced item...

Reviews: