6
West Mountain Radio
Operating Manual
SpeCIFICaTIONS
limits:
Minimum input voltage:
9VDC
Maximum input voltage:
15VDC
Minimum output voltage:
9VDC
Maximum output voltage:
15VDC
Maximum current:
40A Input (per unit)
RF Voltage maximum
100Vp-p (200W)
Current Consumption:
Power Off
1.5mA
Standby
24.4mA
Enabled Booster
40mA
Low Battery/Overtemp
39mA
RF Enable:
RF detect threshold
3.3Vp-p typical. (0.22W)
RF “Turn On” delay
2ms typical
RF “Turn Off” delay range
2-500ms typical
low Battery lockout:
Jumper Selectable
9V, 9.5V, 10V, 10.5V, 11V, 11.5V, 12V
Voltage drop when booster off: 0.76V at 20A load
Efficiency:
Around 90%
Temperature:
Maximum ambient temperature (before shutdown):
32A continuous Output 110ºF
Maximum case temperature (before shutdown):
Sides
115ºF
Bottom center
139ºF
Internal
162ºF
Output Ripple:
Load = 20A (100W xmit) 4.2mV RMS, 12mVp-p
Load = 3A (receive) 3.5mV RMS, 10mVp-p
Connectors:
Anderson Powerpole
®
, 45A
Size:
8.0” x 2.3” x 2.2”
Weight:
0. lbs
Mounting Holes:
Four - 0.175 d, #8 hardware