West Mountain Radio CBA V Manual Download Page 11

11

West Mountain Radio

Operating Manual

Troubleshooting

LED does not light on CBA

• 

Make sure both USB cables ends are in 

securely

• 

If a USB hub is used make sure it is a pow-

ered HUB

• 

Make sure the PC power settings have not 

powered down the USB port

• 

Try another USB port

• 

CBA unit might be damaged

Blinking orange LED

Check the device manager to see if there is a 

driver error flagged by Windows.  If the CBA is 

not listed in the USB section check the “other 

devices” and “unknown devices” sections.  Try 

re-installing the software.

Red flashing LED
        and/or

No or very low voltage shows 

on the right side of the screen 

after a battery is connected.

• 

Verify cable from CBA PowerPoles to battery

• 

Replace the fus

Test stops as fast as it start

• 

Verify when the test is not running that the 

voltage shows right (if not see above)

• 

Verify the test stop criteria is as expected

• 

Expand the chart and if the voltage drops 

very fast you may be setting the current draw 

too high for the battery

During a test, noise appears 

on the chart

• 

As battery contacts heat up due to high cur-

rent the metal changes size and can cause 

resistance changes.

• 

Tighten contacts that can be tightened

• 

Clean contacts that can be cleaned using 

alcohol.

• 

If there is vibration in the environment put 

CBA, cables and battery on a cushioned mat.

• 

Ensure cables that are crimped were properly 

crimped.

During a test, the test abruptly 

stops going to 0 volts.

• 

If the voltage is right when a test is not run-

ning this is due to the resistance of the bat-

tery cable.  Solutions:

• 

Use the remote sense cable to get an accu-

rate reading

• 

Use the extended software to calibrate the 

cable by accounting for the resistance.

• 

Use a heavier CBA to battery cable

TROUBLESHOOTING

Summary of Contents for CBA V

Page 1: ...ountainradio com 1020 Spring City Drive Waukesha WI 53186 262 522 6503 sales westmountainradio com 2021 West Mountain Radio All rights reserved All trademarks are the property of their respective owne...

Page 2: ...stand alone temperature probe USB Port connect CBA to PC Powerpoles use pigtail adapter to connect to battery 25A Fuse use Fuse Puller to replace Status LED see Pg 7 Remote Sense Cable Use the 2 righ...

Page 3: ...or multiple batteries may be compared or overlaid a very useful feature The CBA is ruggedly built and supplied with 45 Amp Powerpole connectors for the battery connection It is small with a high perf...

Page 4: ...erials Never allow a battery reach a temperature that causes it to get so hot that it may be too hot to touch or battery case softens or fumes Recharge the batteries immediately with an appropriate ba...

Page 5: ...onnection to a lead acid battery causing a spark on the terminal Always connect the load or charger last and at a safe distance away from the battery NiCad NiMh and Alkaline Safety Warnings These batt...

Page 6: ...he charge state of each cell in the pack Unbalanced cells can lead to disaster if it permits overcharge of a single cell in the pack If the batteries show any sign of swelling discontinue charging and...

Page 7: ...tant for the exact test termination time The remote sense cable also has a temperature sensor that can be attached to the outside of the battery to terminate a test in case of over heat The Extended s...

Page 8: ...ntain Radio 5 Connect a battery or power supply for testing making sure the polarity is correct WARNING BE CERTAIN THAT YOU HAVE THE POLARITY CORRECT FOR STANDARD CONVENTION PLUS TO PLUS MINUS TO MINU...

Page 9: ...CBA software tests Use of CBA without the GUI Software For use of the CBA without the graphical software provided download the API from the West Mountain Radio website under Support Downloads CBA API...

Page 10: ...solar cells Determine the maximum power they can provide Charge Discharge Perform life cycle test of the battery see how its capacity reacts after user specified number of discharge charge cycles Dut...

Page 11: ...s not running that the voltage shows right if not see above Verify the test stop criteria is as expected Expand the chart and if the voltage drops very fast you may be setting the current draw too hig...

Page 12: ...Mountain Radio Support If you cannot find the answer to a question about using the CBA here in this manual and help files you may get help several other ways Web Support http www westmountainradio com...

Page 13: ...ote sense cable 1 Voltage range for bat tery under test CBA V CBA V Pro 1V to 57V CBA V Pro 100 1V to 100V Sample rate Standard software 1 Second Extended software 50ms to 10 minutes Residual current...

Page 14: ...eriod You will be charged for repair or replacement of the CBA V or accessory made after the expiration of the warranty period West Mountain Radio shall have no liability or responsibility to customer...

Reviews: