background image

www.westmountainradio.com

1020 Spring City Drive

Waukesha, WI 53186

 262-522-6503

[email protected]

©2021 West Mountain Radio, All rights reserved.  All trademarks are 

the property of their respective owners.

CBA V

Summary of Contents for CBA V

Page 1: ...ountainradio com 1020 Spring City Drive Waukesha WI 53186 262 522 6503 sales westmountainradio com 2021 West Mountain Radio All rights reserved All trademarks are the property of their respective owne...

Page 2: ...stand alone temperature probe USB Port connect CBA to PC Powerpoles use pigtail adapter to connect to battery 25A Fuse use Fuse Puller to replace Status LED see Pg 7 Remote Sense Cable Use the 2 righ...

Page 3: ...or multiple batteries may be compared or overlaid a very useful feature The CBA is ruggedly built and supplied with 45 Amp Powerpole connectors for the battery connection It is small with a high perf...

Page 4: ...erials Never allow a battery reach a temperature that causes it to get so hot that it may be too hot to touch or battery case softens or fumes Recharge the batteries immediately with an appropriate ba...

Page 5: ...onnection to a lead acid battery causing a spark on the terminal Always connect the load or charger last and at a safe distance away from the battery NiCad NiMh and Alkaline Safety Warnings These batt...

Page 6: ...he charge state of each cell in the pack Unbalanced cells can lead to disaster if it permits overcharge of a single cell in the pack If the batteries show any sign of swelling discontinue charging and...

Page 7: ...tant for the exact test termination time The remote sense cable also has a temperature sensor that can be attached to the outside of the battery to terminate a test in case of over heat The Extended s...

Page 8: ...ntain Radio 5 Connect a battery or power supply for testing making sure the polarity is correct WARNING BE CERTAIN THAT YOU HAVE THE POLARITY CORRECT FOR STANDARD CONVENTION PLUS TO PLUS MINUS TO MINU...

Page 9: ...CBA software tests Use of CBA without the GUI Software For use of the CBA without the graphical software provided download the API from the West Mountain Radio website under Support Downloads CBA API...

Page 10: ...solar cells Determine the maximum power they can provide Charge Discharge Perform life cycle test of the battery see how its capacity reacts after user specified number of discharge charge cycles Dut...

Page 11: ...s not running that the voltage shows right if not see above Verify the test stop criteria is as expected Expand the chart and if the voltage drops very fast you may be setting the current draw too hig...

Page 12: ...Mountain Radio Support If you cannot find the answer to a question about using the CBA here in this manual and help files you may get help several other ways Web Support http www westmountainradio com...

Page 13: ...ote sense cable 1 Voltage range for bat tery under test CBA V CBA V Pro 1V to 57V CBA V Pro 100 1V to 100V Sample rate Standard software 1 Second Extended software 50ms to 10 minutes Residual current...

Page 14: ...eriod You will be charged for repair or replacement of the CBA V or accessory made after the expiration of the warranty period West Mountain Radio shall have no liability or responsibility to customer...