10
5.
EMERGENCY WORKLIGHT
The Worklight is controlled by an On/Off switch. Make sure the lamp is turned OFF when
the unit is being recharged or stored.
6.
REPLACEMENT PARTS
For replacement parts (bulbs, batteries, fuses, etc.), contact Customer Service:
(954) 584-4446 or toll-free (866) 584-5504.
6.1
Battery replacement
It is recommended that the unit be returned to Customer Service for battery replace-
ment: Contact (954) 584-4446 or toll-free (866) 584-5504.
WARNING
• Do not dispose of the battery in fire as this may result in an explosion
• Before disposing of the battery, protect exposed terminals with heavy-duty electrical
tape to prevent shorting (shorting can result in injury or fire)
• Do not expose battery to fire or intense heat as it may explode
6.2
Battery disposal:
This unit contains a maintenance-free, non-spillable, sealed lead-acid battery. This bat-
tery is fully recyclable and should be accepted at any location that accepts common
automotive starter batteries. Examples of places that accept these batteries are: County
or municipal recycling drop-off centers, scrap metal dealers and retailers who sell auto-
motive replacement lead acid starter batteries. For more information on recycling this
battery, call toll-free (877) 288-7722.
7.
SPECIFICATIONS
Model No . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5406434
Peak Ampere . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1200 Amps
Boost Ampere . . . . . . . . . . . . . . . . . . . . . . . . . . 450 Instantaneous Cranking Amps
HEIGHT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12.75 in. (32.39 cm)
WIDTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 in (27.94 cm)
DEPTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.5 in (13.97 cm)
WEIGHT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 lbs. (7.26 Kg)
Battery Type
12Volt, 19AH/20HR Sealed, Rechargeable
Non-Spillable, Maintenance-free,
Jumper Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Heavy Duty, Welding Cable
Cables Clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 450 Amp, Heavy Duty Clamps
Area Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Three high Intensity White LEDs
Accessory Socket . . . . . . . . . . . . . . . . . . . . . . . . . .Self-Resetting Breaker 20 Amps
DC Charging Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Volt DC
AC Charging Adapter . . . . . . . . . . . . .110/120 Volt AC (700mA, 12 Volt DC Output)
Reverse Polarity Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.5 Volts (min)
9
WARNING:
Do not recharge for more than 3-4 hours maximum using 12 Volt DC method.
3.2
12 Volt DC Charging
1. Insert one end of the DC/DC charging adapter into the 12 Volt DC accessory receptacle
on the vehicle or boat.
2. Insert the plug at the other end of this charging adapter into recharging port on the
front panel of the unit.
3. Charge the unit until the green FULL indicator lights when Charge Switch Indicator
Button is pressed. DO NOT EXCEED 3-4 HOURS MAXIMUM.
4. When charging is completed, remove the power cord and store in a safe place.
3.3
Estimated Battery Life
Table I shows the relationship of the frequency of use between recharging and the expect-
ed number of discharge/recharge cycles.
Table I - Estimated Battery Life between recharges (lifetime of unit’s battery)
Use
Recharges
1
1000+
5
700+
10
500+
4.
O P E R ATION AS A 12 VOLT PORTABLE POWER SUPPLY
1. Lift up the cover of the unit’s 12 Volt DC accessory receptacle.
2. Insert the 12 volt DC plug from the appliance into the receptacle on the unit.
3. Switch on the appliance, and operate as usual.
CAUTION:
DO NOT USE THIS UNIT TO OPERATE APPLIANCES
T H AT DRAW MORE THAN 20 AMPS DC