Hose
(DN 20)
Siphon with
funnel
Air gap
50 mm
Fig. 5.2.2: Installlation instructions for
hygienic drainage of residual water
Residual
flow-
connection
20 mm
Freshwatter-
connection ¾“
Feeder
230 V, 50 Hz
Fig. 5.2: Back view of the model
5.2 Installation air cooled machine
All connections work must be carried out in accordance with the (German) Drinking Water laws as well as the
applicable regulations for the place of use! Also note the technical data and conditions of use in Chapter 4.3.
Always use the hoses, connections and cables supplied with the device for installation!
Air-cooled, built-in type ice cube makers can be installed without taking into account the minimum distances.
However there should be distance to the wall from the
back
side of the machine in order to have enough space for
the connection tubes:
100mm
(see Fig. 5.2.)
Do not cover the front ventilation openings on the housing!
IMPORTANT:
When the device is pushed back in, the water drain tube may become bent or kinked, thus preventing
draining of the water. Please keep an eye on the tube during re-assembly.
5.2.1
Please connect the enclosed inlet hose (DN 8; ¾”–screwing) with the water inlet and with the water tab (cold
water-/ fresh water inlet). Make sure that the rubber sealing is well in place.
5.2.2
Please connect the enclosed outlet hose (DN 20) with the residual water outlet , then run the water drain tube
to the waste water system. Ensure that the tube has a continuous gradient and no bends. Without adequate
gradient of the drain tube, the storage container may overflow and cause water damage
IMPORTANT:
For hygienic reasons, the outlet hose must not be connected directly to the waste water system (see
Fig. 5.2.2).