background image

 

 

 

PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE USING 
THE 

BRV250HD

 AIR HYDRAULIC RIVETER.

 

Safety Instructions 

 

WEAR SAFETY GLASSES OR GOGGLES while using the riveter 

– 

rivets are dispensed at high speed, and may cause damage or 
bodily harm. 

 

DO NOT leave riveter plugged into air supply when not in use. 

 

NEVER point riveter towards or at someone. 

 

KEEP OUT OF REACH OF CHILDREN AT ALL TIMES. 

 

GENERAL INFORMATION

 

Features

 

-      Double O-Seal avoids oil leakage 

-

 

Air Return head design minimizes repairs 

-

 

Adjustable vacuum air flow 
 

 

The 

BRV250HD

 comes with 1/4" nosepiece factory-installed on the tool.

 

 

Specifications: 

 

Tool weight:    

        5.3 pounds 

Length of Tool:             317mm 
Dynamic Air Pressure: 85-100 psi 
Pulling Power (lbs):      3800 
Stroke Length: 

        21mm 

Hydraulic Oil:   

        Texaco R&O-68 or equivalent (36Cst=4.3EI 50

C) 

 

Riveter Accessories

 

Your 

BRV250HD

 Riveter comes with the following accessories:   

 
-   Wrenches (Part No. WP 54005, WP 17S19, WP 63026) 
-   Oil Syringe (Part No. WP 11790) 
-   Tool Hanger (#20) to attach to top of Riveter 

 

 

Tool Preparation before Operation

 

1. 

Prior to each operation of the Riveter, you must choose the size rivet you’ll 
be using.  

If setting 3/16”, 1/4” rivet, make sure the nosepiece on tool 

corresponds to the size of rivet being used as well as jaw pusher.  No 
further changes to the tool are necessary. 

2.  To change nosepiece only: remove Nosepiece (#1) from Riveter.  Unscrew 

by turning Nosepiece counter-clockwise. Choose Nosepiece that 
corresponds to size rivet you are using.  Screw Nosepiece onto Riveter by 
turning clockwise (you will be p

ushing the Jaws into the tool as you’re 

attaching Nosepiece).  Use the 11mm wrench included with accessories to 
loosen and tighten the Nosepiece.    

3.  To do this, remove Nosepiece (#1) and Head (#2) from Riveter. Use 

11mm wrench to loosen Nosepiece.  Unscrew Jaw Housing (#3) 
from Jaw Housing Coupler (#8); when Housing is removed, Jaw 
pusher (#5) as well as 3 pieces of Jaws (#4) will be loose inside 
Housing.  (this size Jaw Pusher is for setting 1/4

” & 3/16” rivets).   

4.  NOTE:  Jaws must be correctly positioned inside Housing for optimal 

performance.  Place 3 pieces of Jaws down into small end of 
Housing, with narrower ends of jaws facing downward and 
protruding out small end of Housing.  The long serrated edges face 
inward towards each other.  MAKE SURE THE 3 PIECES ARE IN 
THE CORRECT POSITION 

– Riveter will not operate correctly if 

Jaw pieces are not properly inserted.  You may need to adjust how 
far each piece of Jaw protrudes through small opening.  This insures 
they are equally distributed. 

5.  Carefully screw Head (#2) back onto tool securely, making sure that 

Jaw pieces stay in place.  Then screw correct Nosepiece onto tool.  
Please note: you will be pushing jaws back into tool slightly as you 
are attaching Nosepiece.  Use 11mm Wrench (included in 
Accessory bag) to tighten Nosepiece onto tool. 

6.  Install Mandrel Bottle (#45) to back of Riveter. 
7.  Cycle air through tool once air connection is hooked up to insure 

correct alignment of jaws. 

Operating Instructions 

 

1. 

Attach a ¼” NPT (Quick Connect Valve) to the Universal Joint (#69).  
Plug air supply into Quick Connect Valve.  Air supply should operate 
at no higher than 100 PSI. 

2.  Squeeze Trigger (#51) to start the vacuum system. 
3.  Insert mandrel of rivet into Riveter. Rivet will be held in Riveter by air 

vacuum. If rivet falls out of tool, vacuum is not strong enough.  
Amount of vacuum can be adjusted via Adjuster Screw (#65) located 
under the Mandrel Bottle area.  Turn this screw counter-clockwise to 
increase vacuum, or clockwise to decrease vacuum.  The longer the 
rivet, the stronger the vacuum must be to hold rivet in place in tool. 

 
4.  Mandrel will be ejected into Mandrel Bottle once Trigger is released. 
5.  NEVER allow Mandrel Bottle to fill more than 1/3 full.  Damage to 

Hydraulic Plunger may occur.  To empty Mandrel Bottle, turn knob at 
end of bottle to reveal bottle opening.  Shake mandrels out of hole.  
Once emptied, turn knob until opening is covered and Mandrel 
Bottle is resealed.

 

 
 
 
 
 
 
 
 