The hydrotherapy spa is designed to seat four adults.
The eight jets provide a relaxing massage to sooth
away stress, and the strength of the water massage
can be adjusted by the air control. The hydrotherapy
spa holds 200 gallons of water and offers a heating
system (70¡F to 104¡F) and a filtration system. 

The guidelines below explain how to properly use the
hydrotherapy spa. Follow these guidelines to maintain
the hydrotherapy spa for your long-term enjoyment.

PLUGGING IN THE HYDROTHERAPY SPA

Once the hydrotherapy spa is filled with water, the
power cord can be plugged in and the spa can be
turned on. Note: The first time the power cord is
plugged in, the spa will turn on automatically.

When connecting the power cord, plug the power cord
directly into a grounded circuit capable of carrying 15
or more amps. No other appliance should be on the
same circuit. Replace the power cord immediately if it
becomes damaged.

The power cord is equipped with a Ground Fault
Circuit Interrupter (GFCI), located at the end of the
power cord. You should always test the GFCI before
using the hydrotherapy spa.  

First, turn on the hydrotherapy spa by pressing the
On/Off Switch on the console. Once the unit is run-
ning, press the GFCI ÒtestÓ button. The hydrotherapy
spa should shut off. Press the ÒresetÓ button. The
hydrotherapy spa should resume normal operation. If
the hydrotherapy spa continues to run after the ÒtestÓ
button is pressed, then the GFCI is damaged. Do not
use the hydrotherapy spa until the GFCI has been
repaired or replaced by a qualified electrician.

TESTING AND TREATING THE WATER

The hydrotherapy spa comes with a starter chemical
pack for maintaining the water in the spa. Disregard
the directions on the individual packages of ÒQUICK
pHix It DOWNÓ and ÒQUICK pHix It UP.Ó However, the
directions on the bottle of ÒNon-chlorine ShoxÓ and
ÒBromine BaseÓ are correct. 

Always keep the chemi-

cals away from children and pets.

The first time you use the spa, you should test and
treat the water. 

You must also treat the water each

time you refill the spa.

Once you have verified that

the spa is functioning properly, and have allowed the
water to circulate for a while, you should remove the
spa cover and add 1/3 of the ÒBromine BaseÓ bottle,
and 1/3 of the ÒNon-chlorine ShoxÓ bottle to the water
in the spa. Allow the water to circulate for five min-
utes. You should now test the pH level of the water by
using the included test strips. Refer to the test strip
packaging for instructions on using the test strips. The
pH reading should be between 7.2 and 7.8. 

If the level is too low, add half of one of the ÒQUICK
pHix It UPÓ packets to the water. Let the water circu-
late through the spa for five minutes. Test the pH level
again. Repeat until the pH level is correct.

If the level is too high, add half of one of the ÒQUICK
pHix It DOWNÓ packets to the water. Let the water cir-
culate through the spa for five minutes. Test the pH
level again. Repeat until the pH level is correct.

See WATER CHEMISTRY on page 14 for information
concerning proper water maintenance.

STARTING THE HYDROTHERAPY SPA

Once you have tested the GFCI, you should verify the
water flow from the pumping unit. Set the air control
on the console to the lowest setting (see USING THE
CONSOLE on page 12). The pumping unit will heat
the water as it pumps. Cover the hydrotherapy spa
with the spa cover. 

The spa cover must be tight

(see SECURING THE SPA COVER on page 11). The
water will heat at about 1.8¡F an hour with the cover
on. If you are using the hydrotherapy spa indoors,
and the room temperature is maintained at 70¡F, it will
take approximately 18 to 22 hours for the water to
reach the set temperature.

The temperature and water flow can be set or
changed by the controls on the console (see USING
THE CONSOLE on page 12).

Test and Reset

Buttons

Grounded circuit capable of

carrying 15 or more amps

GFCI

Using the Hydrotherapy Spa

Summary of Contents for Daybreak 408

Page 1: ...IRECT TO OUR TOLL FREE CUSTOMER HOT LINE The trained techni cians on our customer hot line will provide immediate assis tance free of charge to you CUSTOMER HOT LINE 1 800 999 3756 Mon Fri 6 a m 6 p m...

Page 2: ...where all users of the hydrotherapy spa will be able to see it Whenever the spa is moved the sign must also be moved and reposted near the spa If the sign becomes illegible or if it is lost call our t...

Page 3: ...These high temperatures can cause significant damage such as blistering of the shell surface and warping of the spa shell Any damage caused by sun exposure is not covered under the warranty 9 Do not...

Page 4: ...and lock the spa cover when the hydrotherapy spa is not in use 29 WARNING To reduce the risk of injury The water temperature should never exceed 104 F Temperatures between 100 F and 104 F are consider...

Page 5: ...st be posted where all users of the spa can see and read it See POSTING THE WARNING SIGN on page 2 40 Before entering a spa the user should mea sure the water temperature with an accurate thermometer...

Page 6: ...py spa gives you the specialized treatment you need to feel your best For your benefit read this manual carefully before using the DAYBREAK 408 If you have additional questions please call our Custom...

Page 7: ...f the spa provided you leave access to the motor for ser vice 9 Be sure to note any other considerations such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the hyd...

Page 8: ...e 1 phillips screwdriver You may also need some soap or water A wire connector is provided on the pump motor of this unit to connect a minimum No 8 AWG 804 mm2 solid copper conductor between this unit...

Page 9: ...e Inflatable Cover is lined up with the warning label on the Spa Cover Attach the other three straps on the inside of the Spa Cover 11 through the loops on the Inflatable Cover 4 in the same manner Pl...

Page 10: ...mine Base are correct Always keep the chemi cals away from children and pets The first time you use the spa you should test and treat the water You must also treat the water each time you refill the s...

Page 11: ...re Use of the console D is explained on page 12 of this manual The hydrotherapy spa offers an automatic freeze pro tection If the water temperature falls below 40 F the pump will begin circulating the...

Page 12: ...ll run at high speed pro viding more intense hydrotherapy Press the button a third time and the spa will shut off The spa also features an automatic mode which heats and filters the water when the spa...

Page 13: ...L The spa shell should be cleaned with a mild soap solution Do not use solvents The spa should always be clean and dry before being moved or stored MAINTAINING THE SPA COVER The spa cover should be cl...

Page 14: ...urchase additional test strips or purchase a pH test kit at a pool and spa supply store The pH read ing should be between 7 2 and 7 8 If the level is too low add a pH increaser usually soda ash If the...

Page 15: ...the hydrotherapy spa for the win ter store it in a warm dry location Follow the steps below to winterize the hydrotherapy spa 1 Drain the spa see DRAINING THE HYDROTHERAPY SPA on the previous page an...

Page 16: ...nce is an important part of keeping your spa in top operating condition Use the space below to make any special notes you may want to remember for future reference or to keep a maintenance log Mainten...

Page 17: ...per ature b If you are using the hydrotherapy spa outdoors it may take longer for the water to heat See the chart below for the approximate heating time Air Temperature Heating Time 70 F 24 to 36 hour...

Page 18: ...ey 22 39 1 On Off Switch Assembly 40 1 Air Diverter Knob 41 1 On Off Wire Harness 42 1 See Key 41 43 2 Wire Tie 44 1 Probe Guard Assembly 45 1 Overlay 46 2 Rubber O ring 47 1 Rubber Grommet 48 8 5 16...

Page 19: ...23 50 6 5 24 24 21 14 5 6 12 35 36 36 29 4 46 28 27 47 20 35 36 32 33 33 48 40 39 37 45 15 8 16 7 2 7 9 10 26 13 18 19 18 17 31 30 44 42 38 49 41 22 43 25 7 3 1 34 Exploded Drawing Model No WLHS43080...

Page 20: ...mages caused by or attributable to the following incidents any damage to the wood exterior resulting from improper maintenance or any damage to the wood or tile exteri or attributable to freight misha...

Reviews: