17
PROBLEM: The walking belt slows when walked on
SOLUTION:
a. Use only a single-outlet surge suppressor that meets all of the specifications described on page 11.
b. If the walking belt is overtightened, treadmill perfor-
mance may decrease and the walking belt may be-
come damaged. Remove the key and
UNPLUG THE
POWER CORD.
Using the hex key, turn both idler
roller bolts counterclockwise, 1/4 of a turn. When the
walking belt is properly tightened, you should be able
to lift each edge of the walking belt 2 to 3 in. (5 to 7
cm) off the walking platform. Be careful to keep the
walking belt centered. Then, plug in the power cord,
insert the key, and run the treadmill for a few min-
utes. Repeat until the walking belt is properly tight-
ened.
c. If the walking belt still slows when walked on, see the front cover of this manual.
PROBLEM: The walking belt is off-center or slips when walked on
SOLUTION:
a.
If the walking belt has shifted to the left,
first re-
move the key and
UNPLUG THE POWER CORD.
Using the hex key, turn the left idler roller bolt clock-
wise 1/2 of a turn. Be careful not to overtighten the
walking belt.
If the walking belt has shifted to the
right,
turn the left idler roller bolt counterclockwise 1/2
of a turn. Then, plug in the power cord, insert the key,
and run the treadmill for a few minutes. Repeat until
the walking belt is centered.
SOLUTION:
a. If the walking belt slips when walked on, first remove
the key and
UNPLUG THE POWER CORD.
Using
the hex key, turn both idler roller bolts clockwise, 1/4
of a turn. When the walking belt is correctly tightened,
you should be able to lift each edge of the walking
belt 2 to 3 in. (5 to 7 cm) off the walking platform. Be
careful to keep the walking belt centered. Then, plug
in the power cord, insert the key, and carefully walk
on the treadmill for a few minutes. Repeat until the
walking belt is properly tightened.
a
a
b
2–3 in.
Idler Roller
Bolts