WesAudio Timbre User Manual Download Page 7

WESAUDIO 

4/25/16 

TIMBRE USER MANUAL 

 

 

 

3.

 

Linking compressors 

 

To link two compressors to work in stereo mode, you need simple Jack-Jack 6.3mm mono 

cable. Just connect two compressors together with this cable and activate “Link” function 

on both compressor. From now on both compressors will use common compression signal. 

For proper operation in stereo mode, both compressors should have exactly the same 

settings. 

 

4.

 

Maintenance 

 

Compressor does not require any technical maintenance during the warranty period. Please 

keep it in dry place free from any dust or moisture. 

 

5.

 

Specifications 

 

Frequency response: 20Hz-30kHz (0.5dB) 

THD+N:  up to 1% 

Input impedance:  transformer balanced: 600ohm 

Output impedance:  transformer balanced: 600ohm 

Tubes: 6386, 12AT7, 12AX7, EAA91 

Max gain: 45dB 

Max gain reduction : 40dB 

Mode: single, double,triple 

Balanced output and input (XLR Amphenol) 

Case Rack 2U 

Dimensions : 88 x 483 x 235 mm 

Box dimensions : 55 x 39 x28 cm 

Weight 7kg 

 

Summary of Contents for Timbre

Page 1: ...1 WESAUDIO 4 25 16 TIMBRE USER MANUAL www WesAudio com Timbre User manual EN Copyright 2016 by WesAudio...

Page 2: ...2 WESAUDIO 4 25 16 TIMBRE USER MANUAL Thank You for the purchase of Timbre Timbre All tube Vari mu mono compressor With kind regards Radoslaw Wesolowski...

Page 3: ...3 WESAUDIO 4 25 16 TIMBRE USER MANUAL Table of Contents 1 Instalation 5 2 Front Panel 6 3 Linking compressors 7 4 Maintenance 7 5 Specifications 7 6 Warranty B d Nie zdefiniowano zak adki...

Page 4: ...lor and sweetness It is a vintage style compressor made from the highest quality of components Augmenting the design we have added new features like the third mode of operation with shorter attack tim...

Page 5: ...ced in a ventilated rack cabinet It is recommended to switch ON device at least 15 minutes before operating to ensures best parameters Warning High Voltage inside The device should be connected only t...

Page 6: ...gram controlled characteristic with extra fast attack for maximum density It is only recommended with small amounts of gain reduction 3 Recovery gives six release times The first left position is the...

Page 7: ...s should have exactly the same settings 4 Maintenance Compressor does not require any technical maintenance during the warranty period Please keep it in dry place free from any dust or moisture 5 Spec...

Page 8: ...purchase the product during this time This warranty excludes the following conditions normal wear and tear misuse customer negligence accidental damage unauthorized repair or modification cosmetic da...

Reviews: