WesAudio Beta 76 User Manual Download Page 6

Linking compressors

To link two compressors to work in stereo mode you need special Jack-Jack cable. 
You can purchase it at WesAudio or you can do it yourself as it is shown below:

Zero Set
The 1176LN meter may occasionally need to be calibrated. This is accomplished by adjusting the
Zero Set potentiometer, located through a small hole on the front panel between the Input and Output

Cut if hum appear

 Link connection

M

AINTENANCE

6

W

es

A

udio

It is recommended to switch on device at least 5 min before operating to ensures best parameters.

NOTE! 

The device should be connected only to a ground outlet and proper voltage

Always replace the fuse with the type and value recommended by manufacturer.

230V - IEC 127 20x5mm T315mA
115V - IEC 127 20x5mm T630mA

Warning! High voltage inside ! To reduce the risk of electrical shock do not open the unit.

Installation 

The procedure for adjusting the meter is as follows:
1. Power on the beta76 and wait 15min.
2. Press the Meter GR pushbutton.
3. Set the Input control fully off (turn the knob fully counterclockwise).
4. Use a small screwdriver to slowly adjust the Zero Set potentiometer so that the meter reads 0 dB. 
Watch how the meter settles before completing the calibration.

Summary of Contents for Beta 76

Page 1: ...WesAudio www WesAudio com ßeta 76 LIMITING AMPLIFIER Copyright 2014 by WesAudio User manual EN The art of sound ...

Page 2: ...Thank You for purchasing WesAudio beta76 2 WesAudio INTRODUCTION With kind regards Radoslaw Wesolowski a single channel transformer balanced FET compressor limiter WesAudioBeta76 ...

Page 3: ...s 60 90 150 Hz thanks to which Beta76 is less sensitive to low frequencies The filter is particularly beneficial to the operation of two compressors in a stereo pair which are easily connected with a prepared Jack Jack cable WesAudio Beta76 is a continuation of WesAudio 1176 compressor The introduction of several significant structural improved the original version One of the most important change...

Page 4: ...ease It sets the Release time from 50 millisecond to 1100 milliseconds The release time is fastest when Release knob is in its fully clockwise position and is slowest when it is in its fully counterclockwise SC Filter Link this button determine three side chain hi pass filter frequency 60Hz 90Hz 150Hz and also activate deactivate Link function by pressing it for 2sec Input mode pressing this butto...

Page 5: ...the wrong voltage can damage compressor Before connecting make sure the correct voltage has been selected 9 10 Meter A standard VU meter that displays either the amount of gain reduction or output level depending upon the setting of the Meter Function switch Meter Function Pressing the off button will disable entire 1176 Another three buttons determine what the 1176 front panel VU meter displays G...

Page 6: ... operating to ensures best parameters NOTE The device should be connected only to a ground outlet and proper voltage Always replace the fuse with the type and value recommended by manufacturer 230V IEC 127 20x5mm T315mA 115V IEC 127 20x5mm T630mA Warning High voltage inside To reduce the risk of electrical shock do not open the unit Installation The procedure for adjusting the meter is as follows ...

Page 7: ...CONNECTION 7 WesAudio Balanced XLR connection Balanced Jack XLR connection Beta76 Beta76 Beta76 Beta76 ...

Page 8: ...RECALL SHEET 8 WesAudio ...

Page 9: ... 1dB 20Hz do 20kHz 1 83dB 43dB 230V AC 115 V Time lag 315 mA 230V 630mA 115V Rack 2U 6kg 88 x 483 x 235 mm 3 years Input impedance Output impedance Frequency response THD N SNR Gain AC mains Fuse Case Weight Dimensions Warranty Specifications ...

Page 10: ...WesAudio www WesAudio com Copyright 2014 by WesAudio ...