Supplement smartServo BL 4000

 

 

 

 

October 2022 

Prevention of property damage 

EN 

smartServo BL 4000_Beiblatt_1446849_R1a_EN.docx 

Parameterisation interfaces 

Seite 4 von 4 

1

 

Parameterisation interfaces 

Valid for BL 4000 with IEF-Werner parameter set. 

 

1.)

 

Download and install the "ServoCommander" programme from metronix. 
Link

https://www.metronix.de/metronixweb/downloads/software/ 

The necessary drivers for the BL 4000 parameterisation interfaces are also 
installed. 
 

2.)

 

Connect PC with LAN cable to 

[X21]

 „RTE0“.  

IEF Default-IP: 

10.1.16.254

, Subnetmask: 

255.255.00

 

 
3.)

 

Open the "ServoCommander" program from metronix and select communication 
interface "Ethernet“. 

 

 

Figure 6

 

Select Ethernet interface 

 

The PC requires a suitable, fixed IP setting, such as:  
IP: 10.1.x.x, Subnetmask: 255.255.0.0 
 
Notes: 

 

The 

USB

 interface [X19] is 

not recommended

! It is only suitable for data 

transmission without controller enable. 
Attention: No galvanic isolation. No protection in case of reverse polarity of 
24V / GND. 
Danger for USB interface on PC! 

 

The interface 

[X18] "Ethernet

" is automatically 

deactivated

 if [X21] Realtime 

Ethernet (RTE0) is active (IEF default setting = [X21] active). 

 
 

Summary of Contents for smartServo BL 4000

Page 1: ...istor bridge BL 4100 The bridge for the internal braking resistor must not be present on the BL 41xx under any circumstances There is a risk of irreversible damage to the BL 41xx Top view BL 4100 Figure 1 Connection of a BL 4100 to the supply voltage X9 on top of the unit 1 2 Swapping the top and bottom connectors BL 4100 The supply connector X9 top of the unit and the motor connector X6 bottom of...

Page 2: ... plug 4 Phoenix plug Figure 3 BL amplifier left and S2 FS amplifier right views from the top The supply of the BL 41xx 1 with Weidmüller plug 2 and the S2 1xx FS 3 with Phoenix plug 4 is not compatible Notice The X9 plug of the S2 FS amplifier must not be plugged in to a BL 41xx The wrong pin assignment will lead to irreversible damage to the amplifier and to the USB port of the parameterisation P...

Page 3: ...0 Always connect the shielding before commissioning If the shielding is not correct the EMC behaviour of the BL amplifier is more sensitive than with the servoTEC amplifier In addition material damage to the USB port of the parameterisation PC is possible 2 Assignment Sub D socket X1 I O communication Wiring pin 11 with 24V as with servoTEC S2 FS leads to irreparable damage to the device e g by te...

Page 4: ...onnect PC with LAN cable to X21 RTE0 IEF Default IP 10 1 16 254 Subnetmask 255 255 00 3 Open the ServoCommander program from metronix and select communication interface Ethernet Figure 6 Select Ethernet interface The PC requires a suitable fixed IP setting such as IP 10 1 x x Subnetmask 255 255 0 0 Notes The USB interface X19 is not recommended It is only suitable for data transmission without con...

Reviews: