![wepump WEPRESS Translation Of The Original Instructions Download Page 25](http://html1.mh-extra.com/html/wepump/wepress/wepress_translation-of-the-original-instructions_957077025.webp)
25
GB
Storage
9
GB Storage
If there is danger of frost, dismantle the device and accessories, clean and store them in a place
protected from frost.
Dismantle and store
1. Turn off the device, unplug the mains plug.
2. Open pressure line (turn on water spigot or nozzle), allow water to completely run off.
3. Completely empty the pump and boiler.
4. Dismantle the suction and pressure lines from the device.
5. Store device in a frost-free room (at least 5 °C).
Faults and remedial measures
When something isn’t working…
In many cases small defects can lead to a malfunction. You will usually be able to deal with these
yourself. Please refer to the table below before contacting your local market. This may save you
a lot of effort and quite often money.
Attention!
Danger of damage to the device!
Frost will damage the device and accessories, since they always contain water!
Danger!
Risk of injury!
Improperly performed repairs can lead to the device not functioning safely. This
endangers yourself and your environment.
Error/Fault
Cause
Remedy
Pump does not work.
No power supply?
Check the cable, plug, and the
fuse.
Motor overheats due to high
liquid temperature?
Eliminate cause of overheat-
ing.
(max. liquid temperature 35°C)
Motor overheats due to sealed
ventilation slots?
Residual current protection
switch (FI-switch) activated?
Switch on FI-switch. If it hap-
pens again contact the electric
service partner.
Motor defective?
Contact your local store.
Delivery rate too low.
Not enough pressure.
Water shortage?
Ensure sufficient water supply.
Suction pipe not sealed?
Seal suction pipe, tighten
screwed connections.