35
2D-/3D Profile Sensors
5.5 Default Settings
WeCat3D MLSL
WeCat3D MLWL
Pin function
E/A1
Encoder E1+E2
Encoder E1+E2
E/A2
Encoder E1+E2
Encoder E1+E2
E/A3
Sync Out
Sync Out
E/A4
Sync In
Sync In
I/O settings
E/A1
Operating voltage active
Operating voltage active
E/A2
Operating voltage active
Operating voltage active
E/A3
Push-Pull
Push-Pull
E/A4
Operating voltage active
Operating voltage active
Encoder
Direction of rotation
Independent of direction
Independent of direction
Encoder scaling
0
0
Display
Intensity
Screensaver
Screensaver
Mode
Analysis
Analysis
Operating mode
Profile Sensor
Profile Sensor
Profile
Measuring rate (Hz)
200
175
Signal selection
Strength
Strength
Exposure time (µs)*
150
150
Field of vision (pix)
Offset X
0
0
Width X
1280
2048
Offset Z
0
0
Height Z 1024
2048
Interface
IP address
192.168.100.1
192.168.100.1
Subnet mask
255.255.255.0
255.255.255.0
TCP port
32001
32001
Std. gateway
192.168.100.254
192.168.100.254
MAC address
See OLED display,
interface section
See OLED display,
interface section
Language
English
English
Password OLED
Deactivate/
activate
Deactivated
Deactivated
Change
„0000“
„0000“
Website
password
admin
admin
* A standard exposure time is set upon shipment from the factory. With some surfaces, exposure time has to
be matched to ambient conditions, i.e. increased or reduced.