59
2D/3D Profile Sensors
8.4 Encoder
Encoder
Setting the Encoder’s Direction of Rotation
Rot. Direction
Encod. Reset
3
Back
7
Run
Rot. Direction:
Encoder reset:
Rising: the encoder’s direction of counting is ascending.
Falling: the encoder’s direction of counting is descending.
Encoder settings are reset.
8.5 Display
Various changes can be made to the settings at the display in order to simplify operation of the sensor.
8.5.1 Rotate
Rotate
180° Rotation of the Display
8.5.2 Intensity
Display intensity can be adjusted, for example to assure that the display is still easily legible even in bright
environments.
Display
Display settings
Normal
Power Saver
Screensaver
3
Back
7
Run
Normal:
Power Saver:
Screensaver:
Display intensity is set to the middle value.
If no keys are pressed for a period of one minute, the display
is switched off, and is switched back on as soon as a key is
activated.
If no keys are pressed for a period of 30 seconds, the display is
switched to the display mode and returns to the last used menu
as soon as a key is activated. The colors are inverted every 30
seconds in order to protect the display.
8.5.3 Mode
The sensor is equipped with various display modes which appear in the run display.
Mode
Selection of the display for the “Run” mode
Network
E/A
Analysis
Live Image
3
Back
7
Run
Network:
E/A:
Analysis:
Live Image:
The IP address, MAC adress and the subnet mask are
displayed.
Display of input and output states.
Displays network utilization as a percentage, internal tempera-
ture in °C and signal strength as a percentage.
Displays the current profile image.
Summary of Contents for weCat3D MLSL
Page 20: ...20 Technical Data weCat3D MLWL1x3 0 PP PP weCat3D MLWL1x4 0 PP PP weCat3D MLWL1x5 PP PP 0...
Page 22: ...22 Technical Data weCat3D MLWL2x4 0 PP PP weCat3D MLWL2x5 0 PP PP...
Page 24: ...24 Technical Data weCat3D MLWLxxx weCat3D MLWL1x1 weCat3D MLWL1x2...
Page 71: ...71 2D 3D Profile Sensors...