Project Engineering
78
Input
”override”
SF
penetration
Override
active
Figure 17: Signal sequence with override
DANGER!
• There must be no persons in the danger zone during override.
• The entire danger zone must be clearly visible by the operator during the override.
NOTE!
• While the override is active, the illuminated cap of the ESPE flashes white at 1 Hz.
• Irrespective of the operating mode “Restart inhibit”, the OSSDs also remain in the ON
state when the safety field is cleared and override is ended.