Multi-Beam Safety Light Array
95
NOTE!
• When setting the beam coding, the parameters must be configured on both the emitter
• To deactivate the beam coding, it must be deactivated on both the emitter and receiver
(see
9.4 Parametrization of the receiver with basic function (without display)
The parameter configuration directly on the sensor takes place via the push buttons on the control panel.
Receiver
Menu down
Apply
NOTE!
• If the parameter configuration is interrupted (e.g. due to an interruption in the power
supply), this causes the newly selected settings to be lost. In this case, the most recently
saved settings are active.
• If parameters configuration is started from an error state, all settings are reset (see
9.4.1 Default Settings
Function
Default settings
Restart inhibit
Off
Contactor monitoring
Off
Beam coding
Coding OFF
9.4.2 Calling up the Menu (User Level “Admin”)
• The configuration menu can be called up from the RUN mode, as well as from error mode.
• To prevent unintentional parameter configurations, the call-up of the configuration menu is divided into the
following steps:
1. Press and hold the “Menu down” key (
) until the red “ERROR” LED goes out. (approx. 2 s)
2. Release the key and wait until the red “ERROR” LED lights up again. (approx. 2 s)
3. As soon as the red “ERROR” LED lights up, press and hold the “Menu down” key (
) again until the red
“ERROR” LED goes out. (approx. 2 s)
4. Once the button is released, the settings will be called up (see