29
Safety Interlocks electromagnetic / Safety Switch with interlocking function
4. Technical Data
Ambient Conditions
Temperature range
−25 to 55° C
Storage and transport temperature
−25 to 70° C
Protection
IP65 / IP67
Altitude / installation height above sea level
max. 2000 m
Relative humidity
30 to 95 % (no condensation or icing allowed)
Electrical Data
Supply power
20.0 to 26.4 V DC (stabilized PELV power pack per EN 60204-1)
No-load current I
0
< 0,1 A
Current consumption device with magnet
switched on
Average: < 0,35 A
Peak current:
< 0,55 A / 10 ms
Operating current
Max. 0.6 A plus current via safety outputs
Protection class
III
Rated impulse withstand voltage Uimp
0.8 kV
Overvoltage category
III
Pollution degree
3
Rated insulation voltage Ui
32 V
Rated operating voltage Ue
24 V
Rated operating current Ie
1,1 A
Conditional rated short-circuit current
100 A
External line and equipment protection
2 A gG
Duty cycle of magnet
100 %
Response time
< 150 ms
Risk time
< 150 ms
Ready-state delay
< 4000 ms
Switching frequency
≤
1 Hz
Safety Output OSSD 1 / OSSD 2
Safety output
Semiconductor, NO function, PNP output, short-circuit proof
Number of safety outputs
2
Rated operating voltage Ue1
24 V
Rated operating current Ie1
≤
250 mA
Voltage drop at safety output
≤
1 V
Residual current Ir
≤
0.5 mA
Utilization category
DC-13
Test pulse duration
≤
1,0 ms
Test pulse interval
1000 ms
ZVEI classification
ZVEI CB24I
Source
C1
Sink
C1
Safety Input IN 1 / IN 2
Number of safety inputs
2
Voltage range
−3 to 5 V (low), (stabilized PELV power pack per EN 60204-1)
15 to 30 V (high), (stabilized PELV power pack per EN 60204-1)
Accepted test pulse duration to input signal
≤
1,0 ms
With a test pulse interval of
≥
100 ms
ZVEI classification
ZVEI CB24I
Source
C1, C2, C3
Sink
C1