Retro-Reflex Sensors for Transparent Objects

2.  For Your Safety

2.1 Use for Intended Purpose

The product is based on the following functional principle:

Retro-Reflex Sensors for Clear Glass Recognition 

Reflex sensors for clear glass recognition can be adjusted so precisely that they can reliably recognize highly 
transparent objects such as glass, glass bottles or sheet products. Even shiny, chromed or reflective surfaces 
can be reliably detected thanks to the integrated polarization filter.
The transmitter and receiver are located in a single housing and require a reflector to work. The output 
switches if the light beam between the sensor and reflector is interrupted. The visible light spot of retro-reflex 
sensors facilitates adjustment and commissioning. Depending on the sensor type, even small objects up to 
0.1mm can be reliably detected over long distances.

This product can be used in the following industry sectors:

• Special machinery manufacturing
• Heavy machinery manufacturing
• Logistics
• Automotive industry
• Food industry
• Packaging industry
• Pharmaceuticals industry
• Plastics industry
• Woodworking industry
• Beverages industry

• Consumer goods industry
• Paper industry
• Electronics industry
• Glass industry
• Steel industry
• Aviation industry
• Chemicals industry
• Alternative energy
• Raw materials extraction

2.2 Use for Other than the Intended Purpose

• Not a safety component in accordance with 2006/42/EC (Machinery Directive)
• The product is not suitable for use in potentially explosive atmospheres.
• The product may only be used with accessories supplied or approved by wenglor, or combined with 

approved products. A list of approved accessories and combination products can be accessed at  
www.wenglor.com on the product detail page. 

DANGER!
Risk of personal injury or property damage in case of use for other than the intended 
purpose!

Use for other than the intended purpose may lead to hazardous situations.
• Observe instructions regarding use for intended purpose.

Summary of Contents for P2KK Series

Page 1: ...ns EN Translation of the Original Operating Instruction Subject to change without notice Available as PDF version only Version 1 0 1 Status 09 05 2022 www wenglor com P2KKxxx Retro Reflex Sensors for...

Page 2: ...class 6 3 Technical Data 7 3 1 Technical Data 7 3 1 1 Spot diameter 8 3 1 2 Smallest detectable part 8 3 1 3 Switching distance 8 3 2 Complementary Products 9 3 3 Layout 9 3 4 Control Panel 10 3 5 Sc...

Page 3: ...d by means of symbols and attention getting words Safe use of the product is only possible if these safety precautions and warnings are adhered to The safety precautions and warnings are laid out in a...

Page 4: ...pproved replacement parts Unapproved modification of products These operating instructions do not include any guarantees from wenglor with regard to the described procedures or specific product charac...

Page 5: ...can be used in the following industry sectors Special machinery manufacturing Heavy machinery manufacturing Logistics Automotive industry Food industry Packaging industry Pharmaceuticals industry Pla...

Page 6: ...roduct is modified Personal injury and damage to equipment may occur Non observance may result in loss of the CE marking and the guarantee may be rendered null and void Modification of the product is...

Page 7: ...ge 24 V 20 mA Switching frequency 2000 Hz Switching frequency speed mode 3500 Hz Response time 0 25 ms Response time speed mode 0 14 ms Temperature drift 5 Temperature range 40 60 C Switching output v...

Page 8: ...rs are listed in the following tables Reflector Range RQ100BA 0 1 50 m RE18040BA 0 1 50 m RQ84BA 0 1 50 m RR84BA 0 1 50 m RE9538BA 0 0 70 m RE6151BM 0 1 30 m RR50_A 0 1 50 m RE6040BA 0 1 40 m RE8222BA...

Page 9: ...Suitable mounting technology no Suitable connection technology no 7 IO Link master EFBL001 EFBL003 EP0L001 wTeach2 software DNNF005 Software IO Link Device Tool DNNF019 Hygienically designed screws B...

Page 10: ...f damage con ditionally accept the package and notify the manufacturer of the damage Then return the device making reference to damage in transit 4 2 Storage The following points must be taken into co...

Page 11: ...put Ground for the Trigger Input Analog Output Ground for the Analog Output Block Discharge Valve Output Valve Control Output Valve Control Output 0 V Synchronization Ground for the Synchronization Re...

Page 12: ...arning blinking LED Display LED Diagnosis Cause Elimination Continuous blinking at approx 2 5 Hz Contamination Carefully clean the optic cover with a cloth Aged emitter diode Replace the sensor Unreli...

Page 13: ...Reflector Sensor Reflector Object Sensor Reflector Object Object Sensor Reflector Sensor Reflector Object Sensor Reflector Object Required action in case of fault NOTE Shut down the machine Analyze a...

Page 14: ...settings are possible via the IO Link interface The IODD can be found at www wenglor com in the product s download area 8 Maintenance Instructions NOTE This wenglor sensor is maintenance free Cleaning...

Page 15: ...re 10 2 Change Index Operating Instructions Version Date Description Change 1 0 0 04 08 21 Initial version of the operating instructions 1 0 1 09 05 22 Actualization see section 3 Technical Data on pa...