background image

EN

OY2TA104P0150C

High-Performance Distance Sensor

Operating Instructions

Translation of the Original Operating Instruction

Subject to change without notice

Available as PDF version only

Status: 01.08.2019

wenglor.com

Summary of Contents for OY2TA104P0150C

Page 1: ...A104P0150C High Performance Distance Sensor Operating Instructions Translation of the Original Operating Instruction Subject to change without notice Available as PDF version only Status 01 08 2019 wenglor com ...

Page 2: ...plementary Products 9 4 Mounting Instructions 9 5 Initial Operation 10 5 1 Operation on a controller 10 5 2 Default Settings 10 6 Functional Overview OLED Display 11 6 1 Run 13 6 2 Display 13 6 2 1 Display Mode 13 6 2 2 Display Intensity 14 6 3 Filter 14 6 4 Output Rate 14 6 5 Laser 15 6 6 I O Test 15 6 7 Network 16 6 8 Language 16 6 9 Info 16 6 10 Reset 17 6 11 Password 17 7 Information on EtherC...

Page 3: ...3 8 1 Page layout 24 8 2 General device 25 8 3 Device Settings 26 8 4 Measured Value Settings 27 8 5 Device Test 27 9 Maintenance Instructions 28 10 Proper Disposal 28 11 EU Declaration of Conformity 28 ...

Page 4: ...n in extremely inclined positions It is possible to mount sev eral sensors next to or across from each other without them influencing each other 2 Safety Precautions 2 1 Safety Precautions This operating instruction is part of the product and must be kept during its entire service life Read this operating instruction carefully before using the product Installation start up and maintenance of this ...

Page 5: ...N 60825 1 1 Beam Divergence 2 mrad Light Spot Diameter see table 1 Port Type 100BASE TX PoE Class 1 Response Time 10 ms Temperature Range 25 50 C Reverse Polarity Protection yes Protection Class III Adjustment Menu OLED Housing Plastic Degree of Protection IP68 Connection M12 1 8 pin Webserver yes EoE Ethernet over EtherCAT Control Panel No X2 T10 Interface EtherCAT Light Spot Diameter Working Dis...

Page 6: ... Input confirmation Contactor Monitoring Black Brown Red Orange Yellow Green Blue Violet Grey White Pink Green Yellow Supply Voltage Supply Voltage 0 V Supply Voltage AC Voltage Switching Output NO Switching Output NC Contamination Error Output NO Contamination Error Output NC Input analog or digital Teach Input Time Delay activation Shielding Interface Receive Path Interface Send Path Ready Groun...

Page 7: ...7 3 2 Housing Dimensions 1 Transmitter Diode 2 Receiver Diode ...

Page 8: ...al Green on ESM state Operational Red off No Error Red on Application controller failure Flashing red once Local Error Flashing red twice Process Data Watchdog Timeout EtherCAT Watchdog Timeout Red flashing Red blinking Invalid Configuration MS Module Status Off Green Operate Status Red Device Error Red flashing L A Off No Ethernet device has been connected to the port Green An Ethernet device is ...

Page 9: ...tion Housing Set ZST NN 02 Midspan Adapter Z0029 Switch with PoE ZAC50xN0x 4 Mounting Instructions When using the Sensor follow the corresponding electrical and mechanical regulations standards and safety rules The Sensor must be protected against mechanical influence The Sensor has optimum extraneous light qualities when the background is within the working range ...

Page 10: ...ed out example based on the TwinCat System Manager by Beckhoff First the list Echtzeit Ethernet kompatible Geräte list of all real time Ethernet compatible devices must be requested Once the correct network card has been installed new slave devices can be searched for in E A Geräte I O devices If all configurations are correct the slave devices are now listed in the TwinCAT tree The assemblies can...

Page 11: ...e Change Lock Language Info Reset Password Run Min Medium Max Power save Screensaver Process Text Analyse Network Mode Rotate Intensity Display Filter 1 10 100 2 20 5 50 Laser On Off E A Test Value in µm No of Status Bit OK Warmup OK Too low Too high Measured Value Status Bits Warmup Signal Temperature Output Rate Normal Fast Run Mode Network IP address Subnet Mask Std Gateway ...

Page 12: ...uration menu by pressing any button Note If no setting is made in the configuration menu for a period of 30 s the Sensor returns automatically to the display view Pressing the button again returns the Sensor to the last menu view used If a setting is made it becomes active once you leave the configuration menu Important To prevent any damage to the buttons please do not use any pointed objects for...

Page 13: ...g the button the display is rotated by 180 The rotation is canceled by pressing this button again Intensity Set the display intensity see chapter 7 2 2 6 2 1 Display Mode The measured value in mm and the order number always appear at the sensor s display Selection can be made amongst the following additional displays using the Display Mode menu option Mode Adjust the display device Process Text An...

Page 14: ...a change in the measured values A larger filter improves the reproducibility of the Sensor Filter Number of values for averaging 1 2 5 10 20 50 100 3 Back 7 Run If 1 is selected each measured value is output directly without averaging When ever a value greater than 1 is selected the Sensor takes an average over the selected number of x measured values 6 4 Output Rate The output rate indicates how ...

Page 15: ...ault of the temperature on ok too low or too high List of status bits Number Function Description of when the bit is set Measured value read out 1 General error One of the following bits is set 2 Distance to object too small The current measured value is below the working range Measuring range lower limit 3 Distance to object too large The current measured value is above the working range Measurin...

Page 16: ...P Address Subnet Mask Display of the set Subnet Mask DHCP Display DHCP ON or DHCP OFF Std Gateway Display of the set standard gateway MAC Address Display of the default MAC Address Net Reset Reset network settings to the default settings 6 8 Language The menu language can be changed in the menu item Language The user is automatically prompted for his desired language at initial operation and after...

Page 17: ...operation of the Sensor is disabled after supply power has been interrupted and is only enabled after successfully entering password Change Change password Lock Locking Sensor causes an immediate disabling of operation if activate Password is set to on If the password functionality is activated the password must be entered before each operation of the Sensor After correctly entering the password b...

Page 18: ...1011h Restore default parameters 00h Highest subindex supported Unsigned 8 Ro No 1 1 01h Restore all parameters Unsigned 32 Rw No 0 64616F6Ch restore any other don t rest 1018h Identity Object 00h Highest subindex supported Unsigned 8 Ro No 4 4 01h Vendor ID Unsigned 32 Ro No 0000059Bh 02h Product code Unsigned 32 Ro No 02011D0xh OCP662P0150C OCP352P0150C OCP162P0150C OCP801P0150C 03h Revision num...

Page 19: ...s BOOL Rw No 0 Enabled 0 1 0 Enabled 1 Disabled 02h Key disabling BOOL Rw No 0 Enabled 0 1 0 Enabled 1 Disabled 2100h Display settings 00h Highest subindex supported Unsigned 8 Ro No 5 0 254 5 01h Display mode Unsigned 8 Rw No 0 Process 0 3 0 Process 1 Analysis 2 Text 3 Network 02h Rotate display BOOL Rw No 0 Not rotated 0 1 0 Not rotated 1 Rotated 03h Display intensity Unsigned 8 Rw No 4 Screensa...

Page 20: ...2130h 00h Measured value Unsigned 32 Ro Yes Distance value 2427h 00h Status Unsigned 16 Ro Yes 1 General 2 Object distance too small 3 Object distance too great 4 No signal 5 Contamination 6 Signal too high 7 Warm up procedure 8 Over temperature 9 Under temperature 8000h 00h Measured value timestamp Unsigned 64 Ro Optional FFFFFFFFFFFFFFFFh 2990h InternalObj2 00h Highest subindex supported Unsigne...

Page 21: ... instructions Start Up EtherCAT Device www wenglor com Download Operating Instructions Product Search Order Number General instructions in the chapter Displaying and working with the integrated web server All further steps require an active mailbox and network communication When operated with a controller settings which have been changed via the website are overwritten by the controller or changes...

Page 22: ...22 EN ...

Page 23: ...he Enter button The IP Address is preset to 192 168 100 1 Example http 192 168 100 1 The overview page Device general is not password protected If other pages are accessed a password request appears The following user data is preset in the default settings User name admin Password admin The password can be changed on the Device settings page ...

Page 24: ...ke on the device itself 3 Category selection The web based settings are divided into four categories Device general Overview page with general information about the device Device settings Network and display settings of the device Measured value settings Settings for influencing the measured value of the device Device Test Manual change of the Sensor output in order to test the process 4 Page cont...

Page 25: ...25 8 2 General device After establishing the connection the overview page General device is displayed ...

Page 26: ...ctional description of display settings see chapter 7 2 Display auf Seite 13 Change password An additional window opens in which the new password can be entered Note If the password is forgotten it s only possible to return the device to its default settings by means of a reset at the controller ...

Page 27: ...fault values Note Measured value settings are not reset in this case 8 5 Device Test For functional description of device test see chapter 7 6 I O Test on page 15 The test is activated as soon as at least one parameter is changed The length of the test is limited to 10 minutes Afterwards the test is terminated automatically The remaining time of the test is displayed under the button Switch off an...

Page 28: ...olvents or cleaning agents to clean the Sensor which could damage the device 10 Proper Disposal wenglor sensoric gmbh does not take back unusable or irreparable products When disposing of the products the relevant national regulations for waste disposal apply 11 EU Declaration of Conformity The EU declaration of conformity can be found on our website at www wenglor com in download area ...

Page 29: ...ity if it can be proved that wenglor had knowledge about for the errors in question at the time of creating the operating manual This operating manual is only a general description of technical processes whose implementation does not apply to every individual application If you have specific questions regarding this you can always contact our technical support The information in this operating man...

Reviews: