background image

4

General

1.3 Limitation of Liability

• The product has been developed in consideration of the current state-of-the-art and applicable standards 

and guidelines. Subject to change without notice.

• A valid declaration of conformity can be accessed at www.automationdirect.com in the product’s separate 

download area.

• wenglor sensoric elektronische Geräte GmbH (hereinafter referred to as “wenglor”) excludes all liability in 

the event of:

• Non-compliance with the instructions
• Use of the product for purposes other than those intended
• Use by untrained personnel
• Use of unapproved replacement parts
• Unapproved modification of products

• These operating instructions do not include any guarantees from wenglor with regard to the described 

procedures or specific product characteristics.

• wenglor assumes no liability for printing errors or other inaccuracies contained in these operating instruc-

tions, unless wenglor was verifiably aware of such errors at the point in time at which the operating instruc-
tions were prepared.

1.4 Copyrights

• The contents of these instructions are protected by copyright law.
• All rights are reserved by wenglor.
• Commercial reproduction or any other commercial use of the provided content and information, in particu-

lar graphics and images, is not permitted without previous written consent from wenglor.

Summary of Contents for OPT2172-74

Page 1: ...ctions EN Translation of the Original Operating Instruction Subject to change without notice Available as PDF version only Version 1 0 0 Status 16 11 2020 www wenglor com OPT2172 74 High Performance D...

Page 2: ...ter 8 3 2 Switching Distance Deviation 8 3 3 Layout 9 3 4 Control Panel 10 3 5 Scope of Delivery 11 4 Transport and Storage 11 4 1 Transport 11 4 2 Storage 11 5 Installation and Electrical Connection...

Page 3: ...d by means of symbols and attention getting words Safe use of the product is only possible if these safety precautions and warnings are adhered to The safety precautions and warnings are laid out in a...

Page 4: ...unapproved replacement parts Unapproved modification of products These operating instructions do not include any guarantees from wenglor with regard to the described procedures or specific product cha...

Page 5: ...g industry sectors Special machinery manufacturing Heavy machinery manufacturing Logistics Automotive industry Food industry Packaging industry Pharmaceuticals industry Plastics industry Woodworking i...

Page 6: ...ng and the guarantee may be rendered null and void Modification of the product is impermissible 2 5 General Safety Precautions NOTE These instructions are an integral part of the product and must be k...

Page 7: ...ence 16 mrad Max permissible ambient light 10000 Lux Spot diameter see Table 1 Triple Dot Laser yes Electrical Data Supply power 10 30 V DC Current Consumption Ub 24 V 30 mA Temperature range 40 50 C...

Page 8: ...V Switching Frequency 500 Hz Response Time 1 ms Temperature drift 40 C Tu 50 C 3 Temperature drift 10 C Tu 50 C 2 Output function PNP NC PNP NO NPN NC NPN NO 3 1 Spot diameter Working distance 100 mm...

Page 9: ...9 High Performance Distance Sensors 3 3 Layout OPT2172 OPT2173...

Page 10: ...iver diode 2 emitter diode M3 screw 0 5 Nm Dimensions specified in mm 1 mm 0 03937 3 4 Control Panel OPT2172 74 A 23 06 5a 68 6a 06 teach in key 5a switching status display A1 6a switching status disp...

Page 11: ...the manufacturer of the damage Then return the device making reference to damage in transit 4 2 Storage The following points must be taken into condition with regard to storage Do not store the produc...

Page 12: ...ion Specified torque values must be complied with see section 3 4 Layout page 9 ATTENTION Risk of property damage in case of improper installation The product may be damaged Installation instructions...

Page 13: ...y Voltage Supply Voltage 0 V Supply Voltage AC Voltage Switching Output NO Switching Output NC Contamination Error Output NO Contamination Error Output NC Input analog or digital Teach Input Time Dela...

Page 14: ...nge Increase the sensor s switching distance Reduce distance between sensor and object P1KY005 007 und P1KY012 014 Causes for Triggering the Error Messages A1 A2 Continuous blinking LED Display LED Di...

Page 15: ...ff off on off off off off blinking off Required action in case of fault NOTE Shut down the machine Analyze and eliminate the cause of error with the help of the diagnostics information If the error ca...

Page 16: ...derlying surface is now suppressed Place the object back into the beam emitted by the sensor and check to determine whether or not the sen sor is activated again Detection of Objects Without Interferi...

Page 17: ...e LED output 1 lights up in order to confirm successful teach in Foreground Teach In for Switching Output 2 1 Mount the sensor in accordance with the mounting instructions 2 Position the object in fro...

Page 18: ...uctions 2 Align the sensor to the background 3 Configure or teach in the switching output the switching output function via IO Link 4 The sensor is switched as soon as an object is located between the...

Page 19: ...24 V to the respective input 7 5 External Teach In Teach in output A1 via the teach in input 1 Set the A2 pin function to external teach in 2 Apply 24 V to pin A2 for at least 1 second but for no more...

Page 20: ...with correctly switching outputs and display LEDs 8 Maintenance Instructions NOTE This wenglor sensor is maintenance free Cleaning and inspection of the plug connections at regular intervals are advi...

Page 21: ...TTFd Mean Time to Dangerous Failure 10 2 Change Index Operating Instructions Version Date Description Change 1 0 0 16 11 2020 Initial version of the operating instructions 10 3 EU Declaration of Confo...

Reviews: