Reflex Sensors with Background Suppression

1.  General

1.1 Information Concerning these Instructions

 

• These instructions apply to the products with ID codes OPT2168 and OPT2169.
• They make it possible to use the product safely and efficiently.
• These instructions are an integral part of the product and must be kept on hand for the entire duration of 

its service life.

• Local accident prevention regulations and national work safety regulations must be complied with as well.
• The product is subject to further technical development, and thus the information contained in  

these  operating instructions may also be subject to change. The current version can be found at  
www.automationdirect.com in the product’s separate download area.

NOTE!

The operating instructions must be read carefully before using the product and must be kept 
on hand for later reference.

1.2 Explanations of Symbols

• Safety precautions and warnings are emphasized by means of symbols and attention-getting words
• Safe use of the product is only possible if these safety precautions and warnings are adhered to

The safety precautions and warnings are laid out in accordance with the following principle:

Attention-Getting Word! 
Type and Source of Danger!

Possible consequences in the event that the hazard is disregarded.

 

• Measures for averting the hazard.

The meanings of the attention-getting words, as well as the scope of the associated hazards, are listed below.

DANGER!

This word indicates a hazard with a high degree of risk which, if not avoided, results in death 
or severe injury.

WARNING!

This word indicates a hazard with a medium degree of risk which, if not avoided, may result 
in death or severe injury.

CAUTION!

This word indicates a hazard with a low degree of risk which, if not avoided, may result in 
minor or moderate injury.

ATTENTION!

This word draws attention to a potentially hazardous situation which, if not avoided, may 
result in property damage.

NOTE!

A note draws attention to useful tips and suggestions, as well as information regarding 
efficient, error-free use.

Summary of Contents for OPT2168

Page 1: ...EN OPT2168 OPT2169 Reflex Sensors with Background Suppression Translation of the Original Operating Instruction Subject to change without notice Available as PDF version only Version 1 0 0 Status 16 1...

Page 2: ...7 3 1 1 Spot Diameter 8 3 1 2 Switching Distance Deviation 9 3 2 Layout 9 3 3 Control Panel 10 3 4 Scope of Delivery 10 4 Transport and Storage 11 4 1 Transport 11 4 2 Storage 11 5 Installation and El...

Page 3: ...emphasized by means of symbols and attention getting words Safe use of the product is only possible if these safety precautions and warnings are adhered to The safety precautions and warnings are lai...

Page 4: ...unapproved replacement parts Unapproved modification of products These operating instructions do not include any guarantees from wenglor with regard to the described procedures or specific product ch...

Page 5: ...industry Food industry Packaging industry Pharmaceuticals industry Plastics industry Woodworking industry Consumer goods industry Paper industry Electronics industry Glass industry Steel industry Avi...

Page 6: ...eneral Safety Precautions NOTE These instructions are an integral part of the product and must be kept on hand for the entire duration of its service life In the event of possible changes the respecti...

Page 7: ...wer 10 30 V DC IO Link supply voltage 18 30 V DC 40 60 C Switching output voltage drop 2 V Switching output switching current 100 mA Switching output residual current 50 A Short circuit protection Yes...

Page 8: ...ption 20 mA Switching frequency Response time Switching frequency Interference free Mode Response time Interference free Mode Temperature drift 5 Temperature range 40 60 C Setting method Potentiometer...

Page 9: ...on Kodak white 90 remission 30 50 70 90 110 130 150 2 0 4 6 8 10 Sr mm dSr mm P1KH BLUE Sr Switching Distance dSr Switching Distance Change Black 6 remission Grey 18 remission 3 2 Layout OPT2168 OPT21...

Page 10: ...el 68 05 1K1 30 05 switching distance adjuster 30 switching status indicator contamination warning 68 supply power indicator 3 4 Scope of Delivery Sensor Safety precautions Laser warning label for Cla...

Page 11: ...Then return the device making reference to damage in transit 4 2 Storage The following points must be taken into condition with regard to storage Do not store the product outdoors Store the product in...

Page 12: ...ical influences Make sure that the sensor is mounted in a mechanically secure fashion Specified torque values must be complied with see section 3 Technical Data page 7 ATTENTION Risk of property damag...

Page 13: ...nk Green Yellow Supply Voltage Supply Voltage 0 V Supply Voltage AC Voltage Switching Output NO Switching Output NC Contamination Error Output NO Contamination Error Output NC Input analog or digital...

Page 14: ...approx 5 Hz Short circuit Check electrical wiring and eliminate the short circuit Over temperature Disconnect the sensor from supply power and allow it to cool down Hardware error Replace the sensor...

Page 15: ...ckground or an Undersurface Adjust and securely mount the sensor such that the spot strikes the object to be detected at a right angle Turn the potentiometer all the way to the right Remove the object...

Page 16: ...accept the return of unusable or irreparable products Respectively valid national waste disposal regulations apply to product disposal 10 Appendix 10 1 List of Abbreviations Abbreviation Meaning Tu A...