background image

9

Retro-Reflex Sensor

 

3.3 Layout

OPT2133, OPT2134

1 = Optical axis

OPT2135, OPT2136

1 = Emitter diode
2 = Receiver diode

Summary of Contents for OPT2133

Page 1: ... Translation of the Original Operating Instruction Subject to change without notice Available as PDF version only Version 1 0 0 Status 23 09 19 www wenglor com OPT2133 OPT2134 OPT2135 OPT2136 OPT2137 OPT2138 Retro Reflex Sensor ...

Page 2: ... 2 6 Laser LED Warnings 6 2 7 Approvals and protection class 6 3 Technical Data 7 3 1 Spot diameter 8 3 2 Smallest detectable part 8 3 3 Layout 9 3 4 Control Panel 10 3 5 Scope of Delivery 10 4 Transport and Storage 11 4 1 Transport 11 4 2 Storage 11 5 Installation and Electrical Connection 11 5 1 Installation 11 5 2 Electrical Connection 12 5 3 Diagnostics 13 6 Settings 14 7 I O Link 14 8 Mainten...

Page 3: ...y means of symbols and attention getting words Safe use of the product is only possible if these safety precautions and warnings are adhered to The safety precautions and warnings are laid out in accordance with the following principle Attention Getting Word Type and Source of Danger Possible consequences in the event that the hazard is disregarded Measures for averting the hazard The meanings of ...

Page 4: ...f unapproved replacement parts Unapproved modification of products These operating instructions do not include any guarantees from wenglor with regard to the described procedures or specific product characteristics wenglor assumes no liability for printing errors or other inaccuracies contained in these operating instructions unless wenglor was verifiably aware of such errors at the point in time ...

Page 5: ...ceuticals industry Plastics industry Woodworking industry Consumer goods industry Paper industry Electronics industry Glass industry Steel industry Aviation industry Chemicals industry Alternative energy Raw materials extraction 2 2 Use for Other than the Intended Purpose Not a safety component in accordance with 2006 42 EC Machinery Directive The product is not suitable for use in potentially exp...

Page 6: ...uarantee may be rendered null and void Modification of the product is impermissible 2 5 General Safety Precautions NOTE These instructions are an integral part of the product and must be kept on hand for the entire duration of its service life In the event of possible changes the respectively current version of the operating instructions can be accessed at www automationdirect com in the product s...

Page 7: ...itching current 100 mA Switching output residual current 50 µA Short circuit protection Yes Reverse polarity protected Yes Overload proof Yes Lockable Yes Interface IO Link IO Link version 1 1 Protection class III Mechanical Data Setting method Potentiometer Housing material Plastic Degree of protection IP67 IP68 Lens cover PMMA Order Number Technical Data OPT 2133 2134 2135 2136 Reference Reflect...

Page 8: ...ter Range 1 5 m 3 5 m 7 m Spot diameter 60 mm 120 mm 250 mm Table 1 Range 2 m 5 5 m 11 m Spot diameter 120 mm 270 mm 500 mm Table 2 3 2 Smallest detectable part Range 1 5 m 3 5 m 7 m Smallest detectable part 10 mm 6 mm 15 mm Table 3 ...

Page 9: ...9 Retro Reflex Sensor 3 3 Layout OPT2133 OPT2134 1 Optical axis OPT2135 OPT2136 1 Emitter diode 2 Receiver diode ...

Page 10: ... Potentiometer 40 Nmm Dimensions specified in mm 1 mm 0 03937 3 4 Control Panel 68 05 A32 30 05 switching distance adjuster 30 switching status indicator contamination warning 68 supply power indicator 3 5 Scope of Delivery Sensor Safety precautions BEF SET 14 Spacer sleeves Z1PE002 ...

Page 11: ...improper storage The product may be damaged Storage instructions must be complied with 5 Installation and Electrical Connection 5 1 Installation Protect the product from contamination during installation Observe all applicable electrical and mechanical regulations standards and safety rules Protect the product against mechanical influences Make sure that the sensor is mounted in a mechanically sec...

Page 12: ...ink Green Yellow Supply Voltage Supply Voltage 0 V Supply Voltage AC Voltage Switching Output NO Switching Output NC Contamination Error Output NO Contamination Error Output NC Input analog or digital Teach Input Time Delay activation Shielding Interface Receive Path Interface Send Path Ready Ground Clock Output Input programmable Power over Ethernet Safety Input Safety Output Signal Output Ethern...

Page 13: ...ature Disconnect the sensor from supply power and allow it to cool down Hardware error Replace the sensor Contamination Warning Flowcharts not detected not detected detected beginning contamination not detected not detected detected Retro Reflective Barrier no contamination Object Switching Status Indicator Object Switching Status Indicator Object Switching Status Indicator not detected not detect...

Page 14: ...ge in case of non compliance The system s safety function is disabled Personal injury and damage to equipment Required action as specified in case of fault 6 Settings Align the sensor to the reflector Make sure that the sensor and the reflector are mounted in a mechanically secure fashion Turn the potentiometer all the way to the right Turn the potentiometer back if required detection of small or ...

Page 15: ...accept the return of unusable or irreparable products Respectively valid national waste disposal regulations apply to product disposal 10 Appendix 10 1 List of Abbreviations Abbreviation Meaning Tu Ambient temperature Ub Supply voltage IODD IO Device Description MTTFd Mean Time to Dangerous Failure 10 2 Change Index Operating Instructions Version Date Description Change 1 0 0 23 09 19 Initial vers...