Settings
Required action in case of fault:
NOTE!
• Shut down the machine.
• Analyze and eliminate the cause of error with the help of the diagnostics information.
• If the error cannot be eliminated, please contact wenglor’s support department.
• Do not operate in case of indeterminate malfunctioning.
• The machine must be shut down if the error cannot be unequivocally clarified or reliably
eliminated.
DANGER!
Risk of personal injury or property damage in case of non-compliance!
The system’s safety function is disabled. Personal injury and damage to equipment.
• Required action as specified in case of fault.
6. Settings
• Emitter and receiver must be securely mounted.
• Turn the receivers potentiometer all the way up (right stop).
• Turn back the potentiometer to its left stop.
• Turn the potentiometer up, until the output is activated.
• Keep on turning the potentiometer about 5° in order to increase the switching reserve.
• Place the object to be scanned within the light barrier and check for correct functioning.
Test Input
If the test input is open or connected with minus, the barrier works normally.
If it is connected with plus, the sensor switches off. The barrier is tested via this changing of the switching
status.
7. IO-Link
Further settings are possible via the IO-Link interface. The IODD can be found at www.automationdirect.com
in the product’s download area.