7.4.1. Tolerance
Function
Description
Tolerance
Changing tolerance
Maximum
Very large
Large
Middle
Small
Very small
Minimum
Back
Run
Maximum: Tolerance is set to a maximum value.
Very large: Tolerance is set to a very large value.
Large
Tolerance is set to a large value.
Middle:
Tolerance is set to a medium value.
Small:
Tolerance is set to a small value.
Minimum: Tolerance is set to a very small value.
Minimal: Tolerance is set to a minimum value.
7.5. NO/NC Output Function
Function
Description
NO/NC
Output configuration
NO
NC
Back
Run
NO:
Normally open.
The output closes as soon as an object reaches the switching point.
NC:
Normally closed.
The output opens as soon as an object reaches the switching point.
7.6. NPN PNP
Function
Description
NPN/PNP
Output configuration
PNP
NPN
Push-pull
Back
Run
PNP:
A load or the evaluation device is connected between the negative
pole (supply) and the output. If switched, the output is connected
with
the positive pole via an electric switch.
NPN:
A load or the evaluation device is connected between the positive
pole
(supply) and the output. If the sensor switches, the output is con-
nected
with the negative pole via an electric switch.
Push-pull: Push-pull output.
Acts like an electronic switch which optionally switches the output to
the positive pole or the negative pole.