5
4. Device Features
Optical Data
OPT2013
OPT2014
OPT2012
Working range
0,1…10,1 m
0,1…10,1 m
0,2…6,2 m
Measuring range
10 m
10 m
6 m
Linearity 0,1…5 m
0,05 %
0,2 %
0,2 %
Linearity 5…10 m
0,2 %
0,5 %
0,5 %
Switching hysteresis
3…20 mm
3…20 mm
3…20 mm
Light Source
Laser (red)
Laser (red)
Laser (red)
Wave Length
660 nm
660 nm
660 nm
Service life (amb. temp. = 25 °C)
100000 h
100000 h
100000 h
Laser Protection Class (EN60825-1)
2
2
1
Beam Divergence
<2 mrad
<2 mrad
<2 mrad
Electrical Data
Supply Voltage*
18…30 V DC
18…30 V DC
18…30 V DC
Current Consumption
(operating voltage = 24 V)
<100 mA
<100 mA
<100 mA
Switching Frequency
50 Hz
50 Hz
50 Hz
Response Time
10…200 ms
10…200 ms
10…200 ms
Measure Rate
1…100/s
1…100/s
1…100/s
Temperature Drift
<0,2 mm/k
<0,2 mm/k
<0,2 mm/k
Temperature Range
−25…60 °C
−25…60 °C
−25…60 °C
Number of switching outputs
configurable as PNP
NPN or push-pull
3
2
2
Switching Output Voltage Drop
<2,5 V
<2,5 V
<2,5 V
Switching Output Switching Current
200 mA
200 mA
200 mA
Error Output
yes
yes
yes
Error Output Switching Current
200 mA
200 mA
200 mA
Analog Output
0…10 V
0…10 V
0…10 V
Current Load Voltage Output
<1 mA
<0,5 mA
<0,5 mA
Analog Output
4…20 mA
4…20 mA
4…20 mA
Current Output Load Resistance
<500
W
<500
W
<500
W
Short Circuit Protection
yes
yes
yes
Reverse Polarity Protection
yes
yes
yes
Overload Protection
yes
yes
yes
Resolution
1…12 mm
1…12 mm
1…12 mm
Mechanical Data
Adjustment
Teach-In
Teach-In
Teach-In
Housing
Plastic
Plastic
Plastic
Protection
IP68
IP68
IP68
Connection
M12 × 1, 8-pin M12 × 1, 4-pin M12 × 1, 4-pin
Protection Class
III
III
III
*Supply voltage residual ripple may not exceed 10 % (within the specified voltage range).
**Temperature Drift: 0,4 mm/k at ambient temperature < −10 °C and > 50 °C
Summary of Contents for OPT2012
Page 25: ...25 ...