![Wenglor OPT2001 Operating Instructions Manual Download Page 6](http://html1.mh-extra.com/html/wenglor/opt2001/opt2001_operating-instructions-manual_956817006.webp)
6
EN
OPT2002
OPT2004
OPT2006
Optical Data
Working Range
30…80 mm
40…160 mm
50…350 mm
Measuring Range
50 mm
120 mm
300 mm
Resolution
< 8 µm
< 20 µm
< 50 µm
Resolution (Speed-Mode)
< 12 µm
< 30 µm
< 80 µm
Linearity
0,1 %
0,1 %
0,15 %
Linearity (Speed-Mode)
0,2 %
0,2 %
0,2 %
Light Source
Laser (red)
Laser (red)
Laser (red)
Wave Length
660 nm
660 nm
660 nm
Laser Class
1
1
1
Service Life (25 °C)
100000 h
100000 h
100000 h
max. Ambient Light
10000 Lux
10000 Lux
10000 Lux
Electrical Data
Supply Voltage
18…30 V DC
18…30 V DC
18…30 V DC
Light Spot Size at begin working range
0,5×1 mm
0,5×1,2 mm
0,6×1,5 mm
Light Spot Size at end working range
1×2 mm
1×2,5 mm
1,5×4 mm
Current Consumption (Ub = 24 V)
< 80 mA
< 80 mA
< 80 mA
Measurement Rate
1000/s
1000/s
500/s
Response Time
1000 µs
1000 µs
2000 µs
Response Time (Resolution-Mode)
2000 µs
2000 µs
4000 µs
Temperature Drift
< 5 µm/°C
< 10 µm/°C
< 25 µm/°C
Temperature Range
–25…50 °C
–25…50 °C
–25…50 °C
Analog Output
0…10 V
0…10 V
0…10 V
Current Output Load Resistance
< 1 mA
< 1 mA
< 1 mA
Analog Output
4…20 mA
4…20 mA
4…20 mA
Current Output Load Resistance
< 500 Ohm
< 500 Ohm
< 500 Ohm
Voltagedrop PNP-Error Output
< 2,5 V
< 2,5 V
< 2,5 V
Switching Current PNP-Error Output
< 200 mA
< 200 mA
< 200 mA
Short-Circuit Protection
yes
yes
yes
Reverse Polarity Protection
yes
yes
yes
Mechanical Data
Adjustment
Teach-In
Teach-In
Teach-In
Housing
Plastic
Plastic
Plastic
Protection Mode
IP67
IP67
IP67
Connection
M12×1, 8-pin
M12×1, 8-pin
M12×1, 8-pin
Protection Class
III
III
III
Reference material: Kodak white 90 % remission