16
Installation and Electrical Connection
5.1.3 Permissible Object Dimensions
Permissible object dimensions depend on conveyor
system’s lane width and the utilized mounting system.
The sensor’s inclination angle is not changed when
mounted with the ZPTX001 or ZPTX003 quick mounting
system.
When mounted with the ZPTX002 mounting bracket, the
sensor can be tilted up by as much as 5.5°.
This makes it possible to detect narrower packages,
but the minimum package height is also increased as a
result.
Lane Width
Package Size
≤
600 mm
≤
900 mm
Mounting
ZPTX001/3
ZPTX002
ZPTX001/3
ZPTX002
Px min.
150 mm
100 mm
150 mm
100 mm
Py min.
50 mm
120 mm
100 mm
220 mm
5.2 Electrical Connection
The sensors are equipped with a quick wiring system. This reduces the effort required for completing electri-
cal connections. It must be assured that the socket with the white marking and the plug on the OPT with the
corresponding marking are aligned to each other.
The connection is locked into place by turning the sleeve 180° after the connector socket has been fully
pushed onto the plug.
½
Lane width
Px
7°
Py
3°