background image

5

3.4. Technical Data

Switching Hysteresis

< 15 %

Light Source

Red Light

Wave Length

660 nm

Service Life (Tu = 25 °C)

100000 h

max. ambient Light

10000 Lux

Supply Voltage

10…30 V DC

Current Consumption (Ub = 24 V)

<  40 mA

Switching Frequency

2 kHz

Response Time

250 µs

ON-/OFF-Delay

0…200 ms

Temperature Drift

< 10 %

Temperature Range

–25…60 °C

Switching Output Voltage Drop

< 2,5 V

Switching Output/Switching Current

200 mA

Short Circuit Protection

yes

Reverse Polarity Protection

yes

Overload Protection

yes

Teach Mode

NT, MT, ZT, DT, TP

Adjustment

Teach-In

Housing

Plastic

Full Encapsulation

yes

Degree of Protection 

IP65 

Connection  

M8×1 

Protection Class

III

DIN-Rail mounting  

35 mm 

3.5. Contamination Warning

The contamination warning (included with all ODX202 types) is indicated by means of a blinking red LED (02) 
(with rotary switch in the Run position).

3.6. Contamination Output

The contamination output (included with ODX202P0107) functions as a normally closed contact and is 
switched off if the Sensor is operated within an unreliable range.
Unreliable range: ontamination, misalignment

Summary of Contents for ODX202

Page 1: ...ODX202 Fiber Optic Cable Sensor Operating Instructions Available as PDF only Status 10 10 2016 EN...

Page 2: ...le 7 4 Adjustment 8 4 1 On Delay and Off Delay 8 4 2 Selecting normally closed or normally open function NC NO 9 4 3 Selecting PNP NPN Push Pull 9 4 4 Setting Switching Distance with the potentiometer...

Page 3: ...ts and can thus be recognized from greater distances In barrier operation the color of the object has no effect on the range 2 Safety Precautions This operating instruction is part of the product and...

Page 4: ...0 V T Teach Input 3 2 Housing Dimensions 1 Transmitter Diode 2 Receiver Diode 3 3 EC Declaration of Conformity The EC declaration of conformity can be found on our website at www wenglor com in downl...

Page 5: ...Reverse Polarity Protection yes Overload Protection yes Teach Mode NT MT ZT DT TP Adjustment Teach In Housing Plastic Full Encapsulation yes Degree of Protection IP65 Connection M8 1 Protection Class...

Page 6: ...Status Indicator 02 Contamination Warning 07 Selector Switch 24 Plus Button 25 Minus Button 3 9 Mounting Instructions All applicable electrical and mechanical regulations standards and safety precauti...

Page 7: ...ting of the Sensor 3 9 3 Connecting the plastic fibre optic cable Please cut the plastic fibre optic cable once before using with the SW cutting tool Open the mounting slide with a screwdriver see fig...

Page 8: ...ot lighted up not lighted up 2 blinks pause 2 blinks 200 ms not lighted up lighted up 20 blinks pause 20 blinks Adjusting On Delay Adjusting Off Delay Set rotary selector switch 07 to On Delay Set rot...

Page 9: ...t rotary selector switch 07 to Run 4 3 Selecting PNP NPN Push Pull Set rotary selector switch 07 to NC NO PNP NPN Activate the plus button 24 for 5 seconds Plus button 24 and Minus button 25 blink Rel...

Page 10: ...d Set rotary selector switch 07 to Run 4 5 Setting Switching Distance with the Teach In function The ideal Switching Distance for the object to be recognized is selected automatically with the Teach I...

Page 11: ...tton 25 lights up Activate the minus button 25 again Minus button 25 is no longer illuminated Set rotary selector switch 07 to Run If a second button operation does not take place within 40 seconds th...

Page 12: ...button 24 again The recording mode is ended Plus button 24 is no longer illuminated Set rotary selector switch 07 to Run The switching output is not active during Teach In fig 9 Dynamic Teach In Scan...

Page 13: ...red LED 02 blinks after completion of two point teach in the difference between the two incoming signals is too small 4 6 External Teach In Initialisation The desired teach In process must be selected...

Page 14: ...ig 9 Initialise dynamic Teach In Set rotary selector switch to Teach press and hold the plus button for 5 sec release the plus button set rotary selector switch to Run Set rotary selector switch 07 to...

Page 15: ...utton No button is lighted up Light pulse frequency is max 10 kHz Set rotary selector switch 07 to Run Select a Light pulse frequency Set rotary selector switch 07 to Power Save Activate the plus butt...

Page 16: ...istance possible Activate the minus button 25 The Switching Point is set to the minimal switching distance value possible 5 Maintenance Instructions This wenglor Sensor is maintenance free It is advis...

Reviews: