KNOW YOUR GENERATOR
CONTROL PANEL
1. AC 120V NEMA TT-30R RV Receptacle
Standard RV connector.
2. Engine Switch
This switch makes the engine run or stop.
3. Eco-Mode Switch
Flip this switch to ON to increase fuel economy and
runtime when the load is below 2400W (75% load).
4. Indicator Lights
The output light (green) will turn on when the recep-
tacles have power, the overload light (red) will turn on
if the generator is overloaded, the oil light (yellow) will
turn on if the oil is low.
5. Choke Button
Adjusts the amount of air allowed into the engine dur-
ing startup.
6. CO WATCHDOG Carbon Monoxide Monitor
Measures the accumulation of poisonous CO gas
while the generator is running. If the level of CO gas
gets too high, the CO Watchdog system will automati-
cally shut down the generator. See p. 22 for more in-
formation.
7. Parallel Connection
Connect your generator to another generator with a
parallel kit to gain more power.
8. Overload Reset
If the overload light is ON, press this button to reset
your generator.
9. DC 5V USB Ports
The upper USB port provides 2.1A, while the lower
port provides 1A of power.
10. AC 120V NEMA 5-20R Duplex Receptacles (20A)
Standard household outlets provide 120V 60Hz pow-
er.
11. Circuit Breaker
Push the button to reset the NEMA 5-20R circuit.
12. Grounding Nut
Ground the generator to reduce the risk of electric
shock. Refer to "Step 3 - Ground The Generator" on
page 17.