USING YOUR GENERATOR
PARALLEL OPERATION
The parallel connection ports (Fig. 14) allow you to connect two
WEN generators to increase the total available electrical power.
The WEN Parallel Connection Kit can be purchased from
wenproducts.com.
Follow the instructions included with your
parallel connection kit for proper installation and operation.
IN CASE OF OVERLOAD
If your generator becomes overloaded from too much drawn
wattage, the overload indicator (red) on the control panel will
light up. Follow the instructions below when an overload occurs:
• When you’re close to overloading the generator, the overload
light will start to flash. Reduce the load by turning off and dis-
connecting your electronic device(s) until the overload light turns
off. Then you may continue to operate your generator.
• When you’ve overloaded the generator, the overload light will stay on and the reset button (Fig. 15) will activate
to cut off the output in 3 to 16 seconds, depending on the load. Reduce the load by turning off and disconnecting
your electrical device(s) until the overload light turns off. Wait about five minutes and then press the activated reset
button to reset the circuit. If no power is produced after resetting, turn off and disconnect all electrical devices and
restart your generator.
Fig. 14
Fig. 15
25
LIGHT
MEANING
RESOLUTION
GREEN (POWER INDICA-
TOR)
RED (OVERLOAD)
ON
OFF
Generator output is normal.
No action needed.
ON
Flashing
Continuously
Generator is exceeding rated
output.
Reduce load on generator.
OFF
Flashes 1x
Repeating every 3
seconds
Voltage at alternator is too
low. No electrical output.
Check for loose connections.
Call
1-800-232-1195
for
assistance.
OFF
Flashes 2x
Repeating every 3
seconds
Engine speed is too low.
No electrical output.
Check carburator and stepper
motor. Ensure Eco-Mode is
OFF. Have generator serviced;
call
1-800-232-1195
for
assistance.
OFF
Flashes 3x
Repeating every 3
seconds
Inverter temperature is too
high. No electrical output.
Turn generator off and let cool
down fully (1-2 hours) before
restarting.
OFF
Flashes 5x
Repeating every 3
seconds
Voltage at alternator is too
high. No electrical output.
Have generator serviced; call
1-800-232-1195
for
assistance.
OFF
Flashes 6x
Repeating every 3
seconds
Generator has exceeded rated
output and cut off power to
protect itself. No electrical
output.
Turn OFF and disconnect
loads. Press RESET button on
panel.Reduce load on
generator.
Summary of Contents for 56455i
Page 38: ...WIRE DIAGRAM 38 ...
Page 51: ...NOTES 51 ...